z-logo
Premium
Frequent use of an automated bolus advisor improves glycemic control in pediatric patients treated with insulin pump therapy: results of the Bolus Advisor Benefit Evaluation ( BABE ) study
Author(s) -
Ziegler Ralph,
Rees Christen,
Jacobs Nehle,
Parkin Christopher G.,
Lyden Maureen R.,
Petersen Bettina,
Wagner Robin S.
Publication year - 2016
Publication title -
pediatric diabetes
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.678
H-Index - 75
eISSN - 1399-5448
pISSN - 1399-543X
DOI - 10.1111/pedi.12290
Subject(s) - medicine , glycemic , hypoglycemia , bolus (digestion) , insulin , type 1 diabetes , insulin pump , diabetes mellitus , cohort , pediatrics , anesthesia , endocrinology
Background The relationship between frequency and sustained bolus advisor ( BA ) use and glycemic improvement has not been well characterized in pediatric populations. Objective The objective of this study is to assess the impact of frequent and persistent BA use on glycemic control among pediatric type 1 diabetes patients. Methods In this 6‐month, single‐center, retrospective cohort study, 104 children [61 girls, mean age: 12.7 yr, mean HbA1c 8.0 (1.6)% [64 (17.5) mmol/mol]], treated with the Accu‐Chek Aviva Combo insulin pump, were observed. Frequency of BA use, HbA1c , hypoglycemia (<70 mg/ dL ), therapy changes, mean blood glucose, and glycemic variability (standard deviation) was assessed at baseline and month 6. Sub‐analyses of the adolescent patient use (12 months) and longitudinal use (24 months) were also conducted. Results Seventy‐one patients reported high frequency ( HF ) device use (≥50%); 33 reported low frequency ( LF ) use (<50%) during the study. HF users achieved lower mean ( SE ) HbA1c levels than LF users: 7.5 (0.1)% [59 (1.1) mmol/mol] vs. 8.0 (0.2)% [64 (2.2) mmol/mol], p = 0.0252. No between‐group differences in the percentage of hypoglycemia values were seen at 6 months. HF users showed less glycemic variability (84.0 vs. 94.7, p = 0.0045) than LF users. More HF patients reached HbA1c target of <7.5 at 6 months 66.2% (+16.9) vs. 27.3% (−9.1), p = 0.0056. Similar HbA1c results were seen in adolescents and BA users at 24 months. Conclusion Frequent use of the Accu‐Chek Aviva Combo insulin pump BA feature was associated with improved and sustained glycemic control with no increase in hypoglycemia in this pediatric population.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here