Continuous flow using an entrainer and t‐piece vs drawover apparatus for inhalational induction of anesthesia in children
Author(s) -
Chikumbanje Singatiya,
Bell Graham T.,
Kapatuka Kenneth,
Pollach Gregor
Publication year - 2014
Publication title -
pediatric anesthesia
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.704
H-Index - 82
eISSN - 1460-9592
pISSN - 1155-5645
DOI - 10.1111/pan.12481
Subject(s) - medicine , anesthesia , significant difference
Summary Background Inhalational induction in children is easiest to perform with the Ayres t‐piece & bag (Mapleson F). Drawover anesthesia systems may be used but have not been studied. The aim of this study was to examine the quality of induction of anesthesia in children comparing a continuous flow system using the Farman entrainer and the pediatric t‐piece, to a pediatric drawover system. Methods We conducted a randomized controlled trial in accordance with departmental and institutional standards with 60 subjects who received inhalational induction using either apparatus. Results There was no evidence of a difference in the median Sp0 2 between the two methods ( P = 0.626) neither was there a difference between the method of induction regarding abdominal distension ( P = 0.348) or restraint ( P = 0.186). Induction time using the pediatric drawover apparatus 240 (range 115–605) seconds was significantly greater than the Farman entrainer/t‐piece 146 (range 65–535) seconds ( P < 0.05). Conclusions We consider that this difference is unlikely to be clinically significant in many cases; however, the increased speed using the entrainer and t‐piece may sometimes confer an advantage.