z-logo
Premium
Relevance of esophageal position and temperature on thermal injuries and rhythm outcome in atrial fibrillation ablations
Author(s) -
Stauber Annina,
Kornej Jelena,
Bollmann Andreas,
Hindricks Gerhard,
Sommer Philipp
Publication year - 2020
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1111/pace.13865
Subject(s) - medicine , interquartile range , atrial fibrillation , esophagus , ablation , catheter ablation , cardiology , left atrium , surgery
Background Thermolesions are a dangerous complication of atrial fibrillation (AF) ablation. We aimed to assess the reasons for thermolesions and the effect of esophageal position on recurrences. Methods The study included consecutive patients undergoing AF catheter ablation at Heart Center Leipzig between January and September 2014. We collected data of esophagus localization, temperature, endoscopy, and follow‐up. Results The study included 645 patients into analyses. A total of 626 (97.2%) received a temperature probe. Esophageal position was categorized: (A) behind left pulmonary veins, (B) left ostial, (C) in the middle of left atrium, (D) right ostial, and (E) behind right pulmonary veins. The most frequent esophageal position was B‐C ( n  = 201, 32.1%), followed by B ( n  = 161, 25.7%), and C ( n  = 147, 23.5%). The temperature was highest in A‐B positions (42.04°C) and in D‐E positions (41.70°C). There was a significant correlation between the endoscopically detected esophageal lesions (EDEL) and the esophageal position ( r ² = −.115, P  = .004) and the esophageal temperature ( r ² = .162, P  = .000), but not with body mass index (BMI) ( r ² = −.016, P  = .688). Additional substrate modification in the left atrium resulted in significantly higher esophageal temperatures ( P  < .001) and more frequent EDEL ( P  = .049). An EDEL was found in 15 patients (2.3% of all patients, 5.6% of patients receiving endoscopy). Of those, the median esophageal temperature was 41.8°C (interquartile range [IQR]: 41.2‐42.4). Neither esophageal position nor temperature during ablation was associated with arrhythmia recurrences (both P  > .400). Conclusions EDEL depended on the esophageal position and temperature, but not on BMI. Esophageal position and intraluminal temperature during ablation had no effect on recurrences.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here