Safety and efficacy of zero fluoroscopy transseptal puncture with different approaches
Author(s) -
Baykaner Tina,
Quadros Kenneth K.,
Thosani Amit,
Yasmeh Babak,
Mitra Raman,
Liu Emerson,
Belden William,
Liu Zhigang,
Costea Alex,
Brodt Chad R.,
Zei Paul C.
Publication year - 2020
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1111/pace.13841
Subject(s) - medicine , fluoroscopy , interatrial septum , atrial fibrillation , ablation , perforation , cardiology , catheter ablation , superior vena cava , radiology , surgery , left atrium , punching , materials science , metallurgy
Atrial fibrillation (AF) ablation requires access to the left atrium (LA) via transseptal puncture (TP). TP is traditionally performed with fluoroscopic guidance. Use of intracardiac echocardiography (ICE) and three‐dimensional mapping allows for zero fluoroscopy TP. Objective To demonstrate safety and efficacy of zero fluoroscopy TP using multiple procedural approaches. Methods Patients undergoing AF ablation between January 2015 and November 2017 at five institutions were included. ICE and three‐dimensional mapping were used for sheath positioning and TP. Variable technical approaches were used across centers including placement of J wire in the superior vena cava with ICE guidance followed by dragging down the transseptal sheath into the interatrial septum, or guiding the transseptal sheath directly to the interatrial septum by localizing the ablation catheter with three‐dimensional mapping and replacing it with the transseptal needle once in position. In patients with pacemaker/implantable cardiac defibrillator leads, pre‐/poststudy device interrogation was performed. Results A total of 747 TPs were performed (646 patients, age 63.1 ± 13.1, 67.5% male, LA volume index 34.5 ± 15.8 mL/m 2 , ejection fraction 57.7 ± 10.9%) with 100% success. No punctures required fluoroscopy. Two pericardial effusions, two pericardial tamponades requiring pericardiocentesis, and one transient ischemic attack were observed during the overall ablation procedure, with a total complication rate of 0.7%. There were no other periprocedural complications related to TP, including intrathoracic bleeding, stroke, or death both immediately following TP and within 30 days of the procedure. In patients with intracardiac devices, no device‐related complications were observed. Conclusion TP can be safely and effectively performed without the need for fluoroscopy.