z-logo
Premium
A comparison of postprocedural anticoagulation in high‐risk patients undergoing WATCHMAN device implantation
Author(s) -
Cohen Joshua A.,
Heist E. Kevin,
Galvin Jennifer,
Lee Hang,
Johnson Matthew,
Fitzsimons Michael,
Slattery Kathryn,
Ghoshhajra Brian,
Sakhuja Rahul,
Ha Grace,
Forsch Margaux,
Shi Linsheng,
Danik Jacqueline,
DalBianco Jacob,
Sanborn Danita,
Hung Judy,
Ruskin Jeremy,
Gurol M. Edip,
Mansour Moussa
Publication year - 2019
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1111/pace.13796
Subject(s) - medicine , warfarin , atrial fibrillation , stroke (engine) , major bleeding , incidence (geometry) , randomized controlled trial , surgery , cardiology , mechanical engineering , physics , optics , engineering
Background Left atrial appendage closure (LAAC) is an alternative to long‐term anticoagulation for thromboembolic protection in patients with atrial fibrillation (AF) and high bleeding risk. Short‐term Warfarin use following LAAC is well‐studied, while data pertaining to novel oral anticoagulant (NOAC) use in this setting is less robust. Specifically, data regarding the safety and efficacy of postprocedural NOAC use in high‐risk patients is lacking. Objective To compare the safety and efficacy of Warfarin and NOAC use in a high‐risk patient population undergoing LAAC with the WATCHMAN device. Methods From November 2015 to October 2017, 97 patients underwent LAAC with the WATCHMAN device. All patients were discussed at a multidisciplinary meeting prior to device implantation. Longitudinal data were collected and analyzed for a composite endpoint of stroke and death at 8 months, and major bleeding at 3 and 6 months. Results Among the 90 patients included in the safety and efficacy analysis, 43 were prescribed Warfarin and 47 were prescribed NOACs. Baseline characteristics were comparable between study groups. There were no procedural complications and no significant differences in the incidence of death and stroke at 8 months or major bleeding at 3 and 6 months. Conclusion For patients with AF at high risk of both thromboembolic and hemorrhagic events, NOACs as compared to Warfarin, seem to be safe and effective for short‐term anticoagulation following LAAC with the WATCHMAN device. Further validation in large randomized controlled trials is required.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here