z-logo
Premium
Subcutaneous tissue stiffness of cesarean incision scar by elastography as a predictor of intra‐abdominal adhesions
Author(s) -
Seven Banu,
Yorgancı Ayçağ,
Alkan Mihriban,
Gündüz Özlem,
Keskin H. Levent,
EnginÜstün Yaprak
Publication year - 2020
Publication title -
journal of obstetrics and gynaecology research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.597
H-Index - 50
eISSN - 1447-0756
pISSN - 1341-8076
DOI - 10.1111/jog.14475
Subject(s) - medicine , adhesion , subcutaneous tissue , confidence interval , elastography , surgery , tissue adhesion , urology , nuclear medicine , ultrasound , radiology , chemistry , organic chemistry
Aim This study aimed to investigate whether subcutaneous tissue stiffness of the previous cesarean section (CS) skin incision could predict the severity of the intra‐abdominal adhesions at a repeat CS. Methods In this prospective cross‐sectional study, pregnant women with at least one prior cesarean delivery were included. The subcutaneous tissue stiffness of the previous CS skin scar was measured by shear wave elastography (SWE) on the day of the repeat CS and the intra‐abdominal adhesions were recorded by an adhesion classification scheme specific for CS. Total adhesion score was classified as mild adhesion between 1 and 4, moderate adhesion between 5 and 12, and severe adhesion if ≥13. Results Of the 102 women, 41 (40.2%) had no adhesions, 18 (17.6%) had mild adhesions, 26 (25.5%) had moderate adhesions and 17 (16.7%) had severe adhesions. The mean SWE measurements were significantly higher in the moderate and severe adhesion group than the non‐adhesion and mild adhesion group (51.5 ± 25.3 vs 36.8 ± 22.6, P = 0.003). There was a statistically significant correlation between the preoperative SWE measurements and total adhesion scores (correlation coefficient [ r ] = 0.397, P < 0.001). In receiver–operator characteristics curve analysis, the cut‐off value for moderate or severe adhesions was found to be 36.5 (area under curve = 0.710, %95 confidence interval 0.606–0.815; P < 0.001). With the cut‐off point of ≥36.5, the sensitivity and specificity for the prediction of mild and severe adhesions were 74.4% and 40.5%, respectively. Conclusion Elastographic evaluation of the subcutaneous tissue stiffness of the cesarean incision scar might show the degree of intra‐abdominal adhesions at a repeat CS.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here