z-logo
Premium
Controlled attenuation parameter for the detection of steatosis severity in chronic liver disease: A meta‐analysis of diagnostic accuracy
Author(s) -
Shi KeQing,
Tang JunZhou,
Zhu XueLian,
Ying Li,
Li DeWei,
Gao Jian,
Fang YuXiao,
Li GuiLing,
Song YiJiang,
Deng ZhuJun,
Wu JianMin,
Tang KaiFu
Publication year - 2014
Publication title -
journal of gastroenterology and hepatology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.214
H-Index - 130
eISSN - 1440-1746
pISSN - 0815-9319
DOI - 10.1111/jgh.12519
Subject(s) - medicine , steatosis , confidence interval , meta analysis , receiver operating characteristic , stage (stratigraphy) , gastroenterology , cochrane library , elastography , fatty liver , diagnostic accuracy , liver biopsy , biopsy , ultrasound , radiology , disease , paleontology , biology
Background and Aim Controlled attenuation parameter ( CAP ) is a novel ultrasound‐based elastography method for detection of steatosis severity. This meta‐analysis aimed to assess the performance of CAP . Methods P ub M ed, the C ochrane L ibrary, and the W eb of Knowledge were searched to find studies, published in E nglish, relating to accuracy evaluations of CAP for detecting stage 1 ( S 1), stage 2 ( S 2), or stage 3 ( S 3) hepatic steatosis which was diagnosed by liver biopsy. Sensitivities, specificities, and hierarchical summary receiver operating characteristic ( HSROC ) curves were used to examine CAP performance. The clinical utility of CAP was also evaluated. Results Nine studies, with 11 cohorts were analyzed. The summary sensitivities and specificities values were 0.78 (95% confidence interval [ CI ], 0.69–0.84) and 0.79 (95% CI , 0.68–0.86) for ≥  S 1, 0.85 (95% CI , 0.74–0.92) and 0.79 (95% CI , 0.71–0.85) for ≥ S2, and 0.83 (95% CI , 0.76–0.89) and 0.79 (95% CI , 0.68–0.87) for ≥ S3. The HSROCs were 0.85 (95% CI , 0.81–88) for ≥  S 1, 0.88 (95% CI , 0.85–0.91) for ≥ S2, and 0.87 (95% CI , 0.84–0.90) for ≥  S 3. Following a “positive” measurement (over the threshold value) for ≥ S1, ≥ S2, and ≥ S3, the corresponding post‐test probabilities for the presence of steatosis (pretest probability was 50%) were 78%, 80% and 80%, respectively; if the values were below these thresholds (“negative” results), the post‐test probabilities were 22%, 16%, and 17%, respectively. Conclusions CAP has good sensitivity and specificity for detecting hepatic steatosis; however, based on a meta‐analysis, CAP was limited in their accuracy of steatosis, which precluded widespread use in clinical practice.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here