z-logo
Premium
Effect of tooth brushing on gloss retention and surface roughness of five bulk‐fill resin composites
Author(s) -
O'Neill Catherine,
Kreplak Laurent,
Rueggeberg Frederick A.,
Labrie Daniel,
Shimokawa Carlos Alberto Kenji,
Price Richard Bengt
Publication year - 2017
Publication title -
journal of esthetic and restorative dentistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.919
H-Index - 60
eISSN - 1708-8240
pISSN - 1496-4155
DOI - 10.1111/jerd.12350
Subject(s) - gloss (optics) , toothbrush , materials science , surface roughness , surface finish , composite material , scanning electron microscope , tooth brushing , profilometer , dentifrice , dentistry , chemistry , medicine , brush , coating , inorganic chemistry , fluoride
Objectives To determine the effects of tooth brushing on five bulk‐fill resin based composites (RBCs). Method Ten samples of Filtek Supreme Enamel (control), Filtek One Bulk Fill, Tetric EvoCeram Bulk Fill, SonicFill 2, SDR flow+, and Admira Fusion X‐tra were light cured for 20 seconds using the Valo Grand curing light. After 24 hours storage in air at 37°C, specimens were brushed in a random order using Colgate OpticWhite dentifrice and a soft toothbrush. Surface gloss was measured prior to brushing, after 5,000, 10,000 and 15,000 back and forth brushing cycles. Surface roughness was measured after 15,000 brushing cycles using atomic force microscopy (AFM) and selected scanning electron microscope (SEM) images were taken. The data was examined using ANOVA and pair‐wise comparisons using Scheffe's post‐hoc multiple comparison tests (α = 0.05). Results Surface gloss decreased and the surface roughness increased after brushing. Two‐way ANOVA showed that both the RBC and the number of brushing cycles had a significant negative effect on the gloss. One‐way ANOVA showed that the RBC had a significant effect on the roughness after 15,000 brushing cycles. For both gloss and roughness, brushing had the least effect on the nano‐filled control and nano‐filled bulk‐fill RBC, and the greatest negative effect on Admira Fusion X‐tra. The SEM images provided visual agreement. There was an excellent linear correlation ( R 2  = 0.98) between the logarithm of the gloss and roughness. Conclusion After brushing, the bulk‐fill RBCs were all rougher than the control nano‐filled RBC. The nano‐filled bulk‐fill RBC was the least affected by brushing. Clinical Significance Bulk‐fill RBCs lose their gloss faster and become rougher than the nanofilled conventional RBC, Filtek Supreme Ultra. The nanofilled bulk‐fill RBC was the least affected by tooth brushing.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here