z-logo
Premium
Ventricular activation pattern assessment during right ventricular pacing: Ultra‐high‐frequency ECG study
Author(s) -
Curila Karol,
Jurak Pavel,
Halamek Josef,
Prinzen Frits,
Waldauf Petr,
Karch Jakub,
Stros Petr,
Plesinger Filip,
Mizner Jan,
Susankova Marketa,
Prochazkova Radka,
Sussenbek Ondrej,
Viscor Ivo,
Vondra Vlastimil,
Smisek Radovan,
Leinveber Pavel,
Osmancik Pavel
Publication year - 2021
Publication title -
journal of cardiovascular electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.193
H-Index - 138
eISSN - 1540-8167
pISSN - 1045-3873
DOI - 10.1111/jce.14985
Subject(s) - medicine , cardiology , ventricular outflow tract , ventricular pacing , apex (geometry) , anatomy , heart failure
Background Right ventricular (RV) pacing causes delayed activation of remote ventricular segments. We used the ultra‐high‐frequency ECG (UHF‐ECG) to describe ventricular depolarization when pacing different RV locations. Methods In 51 patients, temporary pacing was performed at the RV septum (mSp); further subclassified as right ventricular inflow tract (RVIT) and right ventricular outflow tract (RVOT) for septal inflow and outflow positions (below or above the plane of His bundle in right anterior oblique), apex, anterior lateral wall, and at the basal RV septum with nonselective His bundle or RBB capture (nsHBorRBBp). The timings of UHF‐ECG electrical activations were quantified as left ventricular lateral wall delay (LVLWd; V8 activation delay) and RV lateral wall delay (RVLWd; V1 activation delay). Results The LVLWd was shortest for nsHBorRBBp (11 ms [95% confidence interval = 5–17]), followed by the RVIT (19 ms [11–26]) and the RVOT (33 ms [27–40]; p  < .01 between all of them), although the QRSd for the latter two were the same (153 ms (148–158) vs. 153 ms (148–158); p  = .99). RV apical capture not only had a longer LVLWd (34 ms (26–43) compared to mSp (27 ms (20–34), p  < .05), but its RVLWd (17 ms (9–25) was also the longest compared to other RV pacing sites (mean values for nsHBorRBBp, mSp, anterior and lateral wall captures being below 6 ms), p  < .001 compared to each of them. Conclusion RVIT pacing produces better ventricular synchrony compared to other RV pacing locations with myocardial capture. However, UHF‐ECG ventricular dysynchrony seen during RVIT pacing is increased compared to concomitant capture of basal septal myocytes and His bundle or proximal right bundle branch.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here