Premium
Incidence of ablation‐induced esophageal injury associated with high‐power short duration temperature‐controlled pulmonary vein isolation using a specialized open‐irrigated ablation catheter: A retrospective single‐center study
Author(s) -
Piringer Robert,
Deneke Thomas,
Foldyna Borek,
Sonne Kai,
Nentwich Karin,
Ene Elena,
Barth Sebastian,
Lüsebrink Ulrich,
Berkovitz Artur,
Halbfass Philipp
Publication year - 2021
Publication title -
journal of cardiovascular electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.193
H-Index - 138
eISSN - 1540-8167
pISSN - 1045-3873
DOI - 10.1111/jce.14883
Subject(s) - medicine , ablation , pulmonary vein , atrial fibrillation , catheter ablation , catheter , surgery , radiofrequency ablation , single center , cardiology
To evaluate short‐term efficacy and incidence of ablation‐induced endoscopically detected esophageal injury in patients undergoing high‐power, short‐duration (HPSD) pulmonary vein isolation using a novel irrigated radiofrequency ablation catheter and ablation generator setup. Methods and Results Atrial fibrillation (AF) patients, who underwent AF ablation using an irrigated radiofrequency ablation catheter specifically designed for a HPSD ablation approach (50 W, with a target Ablation Index of 350 at posterior wall), received postablation esophageal endoscopy after ablation. In total 45 consecutive patients (67 ± 10 years; 58% male; 42% paroxysmal AF) undergoing AF ablation using a specialized ablation catheter (QDOT) were included in the study. Thirty‐one of 45 patients (69%) underwent a first‐time pulmonary vein isolation (Group 1, 67 ± 11 years; 55% male; 48% paroxysmal AF). Fourteen patients (31%) underwent a redo AF procedure (Group 2, 66 ± 8 years; 64% male; 29% paroxysmal AF). Patients undergoing first‐time pulmonary vein isolation were included in the final analysis. In these patients an endoscopically detected esophageal lesion (EDEL) was detected in 5 of 31 (16%) patients (erosion n = 2, ulcer n = 3). Mean contact force at posterior wall ablation sites was significantly lower in patients with postprocedural EDEL compared with patients without EDEL (11.9 ± 0.8 g vs. 15.6 ± 4.7 g). Conclusion PVI using a specialized high‐power ablation catheter in conjunction with a HPSD ablation approach results in a 16% incidence of EDEL in first AF ablation candidates. Future studies evaluating high‐power short duration ablation strategies should include esophageal endoscopy to estimate the risk of clinically relevant esophageal complications.