Fluoroscopy reduction during device implantation by using three‐dimensional navigation. A single‐center experience
Author(s) -
Larsen Timothy R.,
Saini Aditya,
Moore Jessica,
Huizar Jose F,
Tan Alex Y,
Ellenbogen Kenneth A.,
Kaszala Karoly
Publication year - 2019
Publication title -
journal of cardiovascular electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.193
H-Index - 138
eISSN - 1540-8167
pISSN - 1045-3873
DOI - 10.1111/jce.14102
Subject(s) - medicine , fluoroscopy , interquartile range , nuclear medicine , coronary sinus , kerma , ostium , single center , radiology , surgery , dosimetry , cardiology
Background and objectives The use of nonfluoroscopic three‐dimensional electroanatomic mapping (3DM) systems reduces radiation exposure during ablation procedures. In this study, we sought to determine the value of 3DM during routine device implant procedures. Methods Seventy nonselected patients underwent implantation of a single chamber, dual chamber, or biventricular device guided by Ensite (Abbott Laboratories) to limit fluoroscopy use and compared with 70 consecutive patients, who underwent matching procedures with standard fluoroscopy use (FL) in the period immediately preceding the use of 3DM. The venous anatomy, right atrium, and ventricle and coronary sinus were mapped with 0.035 inch J‐wire, quadripolar catheter, and/or angioplasty wire. The leads were advanced under real‐time visualization in Ensite. Results 3DM reduced both fluoroscopy time and dose. Median fluoroscopy time for FL vs 3DM was 5.5 minutes (interquartile range [IQR]: 3.8‐8.1) vs 0.9 minutes (IQR: 0.6‐1.9) ( P  < .001) for single chamber devices, 6.3 minutes (IQR: 5.1‐7.9) vs 3.3 minutes (IQR: 1.9‐4) ( P  < .001) for dual‐chamber devices, and 28.6 minutes (IQR: 19.6‐36.2) to 14.7 minutes (IQR: 10.4‐22.3) ( P  = .009) for biventricular devices, respectively. The median air kerma for FL vs 3DM was 15.4 mGy (IQR: 8.1‐30.2) vs 4 mGy (IQR: 1.8‐8) ( P  < .001) for single chamber devices, 16 mGy (IQR: 12‐18.5) to 9.4 mGy (IQR: 7.5‐11.3) ( P  = .001) for dual‐chamber devices, and 324 mGy (IQR: 143‐668.7) to 115 mGy (IQR:77‐204) ( P  = .014) for biventricular devices, respectively. There were no procedural complications. At 3‐month follow‐up, there was no difference in voltage threshold measurements between the groups. Conclusion The use of 3DM leads to significantly reduced fluoroscopy time and fluoroscopy dose during routine device implantation.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here