Performance of Anatomically Designed Quadripolar Left Ventricular Leads: Results from the NAVIGATE X4 Clinical Trial
Author(s) -
MITTAL SUNEET,
NAIR DEVI,
PADANILAM BENZY J.,
CIUFFO ALLEN,
GUPTA NIGEL,
GALLAGHER PETER,
GOLDNER BRUCE,
HAMMILL ERIC F.,
WOLD NICOLAS,
STEIN KENNETH,
BURKE MARTIN
Publication year - 2016
Publication title -
journal of cardiovascular electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.193
H-Index - 138
eISSN - 1540-8167
pISSN - 1045-3873
DOI - 10.1111/jce.13044
Subject(s) - medicine , lead (geology) , cardiac resynchronization therapy , cardiology , spiral (railway) , complication , surgery , heart failure , ejection fraction , mathematical analysis , mathematics , geomorphology , geology
Anatomically Designed Quadripolar LV Leads Introduction The safety and efficacy of a novel family of quadripolar left ventricular (LV) pacing leads designed to pace from nonapical regions of the LV with low pacing capture thresholds was studied in patients undergoing implantation of a cardiac resynchronization therapy defibrillator (CRT‐D). Methods and Results Patients receiving a CRT‐D were implanted with 1 of 3 ACUITY X4 leads (Spiral Long, Spiral Short, or Straight), designed to address coronary venous anatomical variability. Electrical performance and LV lead related complications were evaluated 3 and 6 months post implantation, respectively. 764 patients (68 ± 11 years, 66% male) were enrolled; 738 (97%) successfully implanted with an ACUITY X4 lead (Spiral L, n = 239, 31%; Spiral S, n = 281, 37%; Straight, n = 218, 29%). A targeted threshold ≤2.5 V was achieved in 644 (94%) patients. The median threshold from the best proximal electrode was lower than the tip electrode (0.9 V [IQR 0.7, 1.3] vs. 1.3 V [IQR 0.7, 2.5], p< 0.001) on Spiral leads. Irrespective of lead implanted, one of the proximal electrodes was the programmed cathode in most patients. The overall LV complication‐free rate was 98%. LV lead dislodgment occurred in 8 (1%) patients. PNS occurred in 58 (8%) patients, but only 3 (0.4%) patients required surgical intervention. Conclusion The ACUITY X4 LV leads had low pacing thresholds particularly from proximal electrodes, a high incidence of pacing from the nondistal electrode, and low likelihood of dislodgment or PNS requiring surgical intervention. ( ClinicalTrials.gov Identifier: NCT02071173)

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here