z-logo
Premium
Biophysical Modeling Predicts Ventricular Tachycardia Inducibility and Circuit Morphology: A Combined Clinical Validation and Computer Modeling Approach
Author(s) -
CHEN ZHONG,
CABRERALOZOYA ROCIO,
RELAN JATIN,
SOHAL MANAV,
SHETTY ANOOP,
KARIM RASHED,
DELINGETTE HERVE,
GILL JASWINDER,
RHODE KAWAL,
AYACHE NICHOLAS,
TAGGART PETER,
RINALDI CHRISTOPHER ALDO,
SERMESANT MAXIME,
RAZAVI REZA
Publication year - 2016
Publication title -
journal of cardiovascular electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.193
H-Index - 138
eISSN - 1540-8167
pISSN - 1045-3873
DOI - 10.1111/jce.12991
Subject(s) - medicine , ventricular tachycardia , cardiology
VT Stimulation In Silico Introduction Computational modeling of cardiac arrhythmogenesis and arrhythmia maintenance has made a significant contribution to the understanding of the underlying mechanisms of arrhythmia. We hypothesized that a cardiac model using personalized electro‐anatomical parameters could define the underlying ventricular tachycardia (VT) substrate and predict reentrant VT circuits. We used a combined modeling and clinical approach in order to validate the concept. Methods and results Non‐contact electroanatomic mapping studies were performed in 7 patients (5 ischemics, 2 non‐ischemics). Three ischemic cardiomyopathy patients underwent a clinical VT stimulation study. Anatomical information was obtained from cardiac magnetic resonance imaging (CMR) including high‐resolution scar imaging. A simplified biophysical mono‐domain action potential model personalized with the patients’ anatomical and electrical information was used to perform in silico VT stimulation studies for comparison. The personalized in silico VT stimulations were able to predict VT inducibility as well as the macroscopic characteristics of the VT circuits in patients who had clinical VT stimulation studies. The patients with positive clinical VT stimulation studies had wider distribution of action potential duration restitution curve (APD‐RC) slopes and APDs than the patient with a negative VT stimulation study. The exit points of reentrant VT circuits encompassed a higher percentage of the maximum APD‐RC slope compared to the scar and non‐scar areas, 32%, 4%, and 0.2%, respectively. Conclusions VT stimulation studies can be simulated in silico using a personalized biophysical cardiac model. Myocardial spatial heterogeneity of APD restitution properties and conductivity may help predict the location of crucial entry/exit points of reentrant VT circuits.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here