z-logo
Premium
Cardiac Resynchronization Therapy Delivered Via a Multipolar Left Ventricular Lead is Associated with Reduced Mortality and Elimination of Phrenic Nerve Stimulation: Long‐Term Follow‐Up from a Multicenter Registry
Author(s) -
BEHAR JONATHAN M.,
BOSTOCK JULIAN,
ZHU LI ADRIAN PO,
CHIN HUI MEN SELINA,
JUBB STEPHEN,
LENT EDWARD,
GAMBLE JAMES,
FOLEY PAUL W.X.,
BETTS TIM R.,
RINALDI CHRISTOPHER ALDO,
HERRING NEIL
Publication year - 2015
Publication title -
journal of cardiovascular electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.193
H-Index - 138
eISSN - 1540-8167
pISSN - 1045-3873
DOI - 10.1111/jce.12625
Subject(s) - medicine , lead (geology) , cardiac resynchronization therapy , cardiology , heart failure , ventricular pacing , univariate analysis , multivariate analysis , ejection fraction , geomorphology , geology
Lower Mortality and Eliminated PNS Associated with Quadripolar Leads Introduction Cardiac resynchronization therapy (CRT) using quadripolar left ventricular (LV) leads provides more pacing vectors compared to bipolar leads. This may avoid phrenic nerve stimulation (PNS) and allow optimal lead placement to maximize biventricular pacing. However, a long‐term improvement in patient outcome has yet to be demonstrated. Methods A total of 721 consecutive patients with conventional CRTD criteria implanted with quadripolar (n = 357) or bipolar (n = 364) LV leads were enrolled into a registry at 3 UK centers. Lead performance and mortality was analyzed over a 5‐year period. Results Patients receiving a quadripolar lead were of similar age and sex to those receiving a bipolar lead, although a lower proportion had ischemic heart disease (62.6% vs. 54.1%, P = 0.02). Both groups had similar rates of procedural success, although lead threshold, impedance, and procedural radiation dose were significantly lower in those receiving a quadripolar lead. PNS was more common in those with quadripolar leads (16.0% vs. 11.6%, P = 0.08), but was eliminated by switching pacing vector in all cases compared with 60% in the bipolar group (P < 0.001). Furthermore, LV lead displacement (1.7% vs. 4.6%, P = 0.03) and repositioning (2.0% vs. 5.2%, P = 0.03) occurred significantly less often in those with a quadripolar lead. All‐cause mortality was also significantly lower in the quadripolar compared to bipolar lead group in univariate and multivariate analysis (13.2% vs. 22.5%, P < 0.001). Conclusions In a large, multicenter experience, the use of quadripolar LV leads for CRT was associated with elimination of PNS and lower overall mortality. This has important implications for LV pacing lead choice.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here