Premium
失禁性皮炎类红斑的结果测量仪器:系统综述
Author(s) -
De Meyer Dorien,
Gabriel Sabrina,
Kottner Jan,
Van Damme Nele,
Van den Bussche Karen,
Verhaeghe Sofie,
Van Hecke Ann,
Beeckman Dimitri
Publication year - 2019
Publication title -
journal of advanced nursing
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.948
H-Index - 155
eISSN - 1365-2648
pISSN - 0309-2402
DOI - 10.1111/jan.14102
Subject(s) - medicine , checklist , cinahl , erythema , dermatology , medline , reliability (semiconductor) , urinary incontinence , quality of life (healthcare) , physical therapy , surgery , psychology , psychological intervention , nursing , power (physics) , physics , quantum mechanics , political science , law , cognitive psychology
Aim To: (a) examine which outcome measurement instruments for erythema associated with incontinence‐associated dermatitis (IAD) with supporting evidence about measurement properties are available; (b) evaluate the methodological quality of the studies and the quality of the measurement properties; and (c) identify eligible instruments to measure erythema in incontinence‐associated dermatitis research. Design Systematic review. Data sources MEDLINE, EMBASE, CINAHL and CENTRAL were systematically searched until July 2018 (update December 2018). Additional input was gathered from 151 incontinence‐associated dermatitis experts. Cited and citing references of included studies were screened. Review Methods The COSMIN Risk of Bias checklist was applied to evaluate the methodological quality of the studies. Reported measurement properties were rated against criteria for good measurement properties. Results Fourteen studies, describing 10 measurement instruments, were included. In five instruments, erythema was captured as a separate concept, two studies provided empirical evidence about the measurement properties. The most studied measurement properties were reliability (9 studies), measurement error (4 studies) and criterion validity (4 studies). In one study, internal consistency was examined. Conclusion No instrument measuring exclusively erythema associated with incontinence‐associated dermatitis exists. There is no single composite incontinence‐associated dermatitis measurement instrument that outperforms others. Development or adaption of an instrument to measure erythema associated with incontinence‐associated dermatitis is one option to solve this challenge. Impact The evidence about measurement properties of instruments measuring erythema associated with incontinence‐associated dermatitis has not been summarized to date. The lack of an instrument should trigger activities to measure this domain accurately in future clinical trials.