z-logo
open-access-imgOpen Access
Effects of Syringe Type and Storage Temperature on Results of Blood Gas Analysis in Arterial Blood of Horses
Author(s) -
Picandet Valerie,
Jeanneret Stephanie,
Lavoie JeanPierre
Publication year - 2007
Publication title -
journal of veterinary internal medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.356
H-Index - 103
eISSN - 1939-1676
pISSN - 0891-6640
DOI - 10.1111/j.1939-1676.2007.tb02993.x
Subject(s) - syringe , medicine , arterial blood , anesthesia , blood collection , partial pressure , blood pressure , carbon dioxide , arterial blood gas analysis , surgery , oxygen , emergency medicine , chemistry , organic chemistry , psychiatry
Background:Results of arterial blood gas analysis can be biased by pre‐analytical factors, such as time to analysis, syringe type, and temperature during storage. However, the acceptable delay between time of collection and analysis for equine arterial blood gas remains unknown. Hypothesis:Dedicated plastic syringes provide better stability of arterial blood gases than multipurpose plastic syringes. Animals:Eight mares, 1 stallion, and 1 gelding, ages 3 to 10 years old. Methods:Arterial blood samples were collected in a glass syringe, a plastic syringe designated for blood gas collection, and a multipurpose tuberculin plastic syringe. Blood samples were stored at ambient temperature or in iced water. For each sample, partial pressure of oxygen in arterial blood (PaO 2 ), partial pressure of carbon dioxide in arterial blood (PaCO 2 ), and pH were measured within a few minutes of collection and at 5, 20, 30, 60, 90, and 120 minutes after collection. Results:Collection into glass syringes stored in iced water provided adequate PaO 2 results for up to 117 ± 35 minutes, whereas blood collected in either of the plastic syringes resulted in a variation >10 mm Hg after 10 ± 3 to 17 ± 2 minutes, depending on the storage conditions. Plastic syringes kept at ambient temperature offered more stability for PaCO 2 analysis because they could be stored up to 83 ± 16 minutes without significant variations. Values of pH did not show variations more than 0.02 for the first hour, irrespectively of storage condition. Conclusions and Clinical Importance: Glass syringes placed on ice are preferable for analysis of PaO 2 . Blood collected in plastic syringes should be analyzed within 10 minutes, irrespective of the storage temperature, to ensure the accuracy of PaO 2 values.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here