z-logo
open-access-imgOpen Access
Decreased Systolic Function and Inadequate Hypertrophy in Large and Small Breed Dogs with Chronic Mitral Valve Insufficiency
Author(s) -
Borgarelli Michele,
Tarducci Alberto,
Zanatta Renato,
Haggstrom Jens
Publication year - 2007
Publication title -
journal of veterinary internal medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.356
H-Index - 103
eISSN - 1939-1676
pISSN - 0891-6640
DOI - 10.1111/j.1939-1676.2007.tb02929.x
Subject(s) - medicine , cardiology , heart failure , muscle hypertrophy , breed , diastole , mitral valve , fractional shortening , left ventricular hypertrophy , ejection fraction , blood pressure , zoology , biology
Background : Systolic dysfunction associated with chronic mitral valve insufficiency (CMVI) has been demonstrated in experimental animal models and large breed (LB) dogs but has been reported as an uncommon finding in small breed (SB) dogs with naturally occurring disease. It has been suggested the myocardial failure could be, in part, because of an insufficient increase in left ventricular mass. Hypothesis : To test if SB and LB dogs with CMVI and moderate heart failure have systolic dysfunction and if they have adequate eccentric hypertrophy. Animals : Data from 38 SB and 18 LB dogs affected with CMVI were compared retrospectively with results from 2 groups of normal dogs (17 SB and 32 LB) Methods : Systolic function was investigated echocardiographically by using percentage fractional shortening (FS), the ratio between observed and expected end‐systolic diameter (ESD/ESDe), and end‐systolic volume index (ESVI). Left ventricular hypertrophy was estimated by using the ratio between the thickness of the left ventricular free wall and the radius in diastole (h/R). Results : Both affected SB and LB dogs had a significantly increased FS and ESVI (FS% SB 45.6 + 8.04 versus 40.06 + 8.9, P < .05; FS% LB 33.64 + 8.61 versus 27.3 + 7.3 P < .05; ESVI SB 30.0 ± 2.3 mL/m 2 versus 21.18 ± 13.9 mL/m 2 , P < .05; ESVI LB 83.22 ± 43.84 mL/m 2 versus 36.43 ± 13.30 mL/m 2 versus P < .001). The h/R in affected animals was decreased (0.53 ± 0.11 versus 0.41 ± 0.12, P < .05 SB; 0.47 ± 0.11 versus 0.38 ± 0.09, P < .05, LB). Conclusions and Clinical Importance : Data from this study indicate that dogs with moderate heart failure caused by CMVI have systolic dysfunction. Inadequate hypertrophy of the left ventricle may be, in part, responsible for this finding.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here