Premium
Kinetics of Hydrothermal Reactions of Minerals in Near‐critical and Supercritical Water
Author(s) -
Ronghua ZHANG,
Shumin HU,
Xuetong ZHANG
Publication year - 2000
Publication title -
acta geologica sinica ‐ english edition
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.444
H-Index - 61
eISSN - 1755-6724
pISSN - 1000-9515
DOI - 10.1111/j.1755-6724.2000.tb00483.x
Subject(s) - albite , dissolution , supercritical fluid , hydrothermal circulation , mineralogy , chemistry , kinetics , thermodynamics , geology , materials science , metallurgy , quartz , physics , organic chemistry , seismology , quantum mechanics
This work presents new experimental results on the kinetics of mineral dissolution in near‐critical and supercritical water in a temperature range ( T ) from 25 to 400°C and a constant pressure of 23 MPa. Kinetic experiments were carried out by using a flow reactor (packed bed reactor) of an open system. The dissolution rates of albite and magnetite were measured under these experimental conditions. Na, Al and Si release rates for albite dissolution in water were measured as a function of the temperature and flow velocity in the reaction system. The maximum release rates of Na, Al and Si of albite dissolution in the hydrothermal flow systems under different flow velocities were always obtained at 300°C, that is to say, the maximum albite dissolution rates in the flow systems, regardless of different flow rates, were repeatedly measured at 300°C. Results indicate a wide fluctuation in albite dissolution rates occurring close to the critical point of water. The dissolution rates increased when the temperatures increased from 25 to 300°C and decreased when the temperatures increase from 300 to 400°C. At some flow velocities, the dissolution rates rose as the temperature surpassed 374°C. Albite dissolution was incongruent in water at most temperatures. It was only at 300°C that albite dissolution was congruent. The albite dissolution from 25 to 300°C (at 23 MPa) will change from incongruent to congruent, whereas from subcritical 300 to 400°C (at 23 MPa), the dissolution will change from congruent to incongruent. The release ratio of Al/Si (or Na/Si) is positive at T <300°C, and it is negative at T >300°C. The dissolution rates of magnetite in water increased with increasing T until T at the critical point of water or around it. The authors believe that this is caused by the wide fluctuations in water properties under the conditions from the near‐critical to supercritical state.