Subject(s) - medicine , catheter , heparin , thrombus , thrombosis , surgery , dialysis catheter , dialysis , anesthesia
SUMMARY A prospective analysis was conducted comparing dysfunction attributable to catheter thrombosis in subjects who received a heparin catheter lock three times a week (n = 15) to those who received a heparin lock six times a week (n = 15) immediately after the insertion of a temporary haemodialysis catheter. Thrombus related catheter removal occurred in two patients in control but no patients in the experiment group. Heparin locking six times a week was found to be effective in prolonging the mean of the first day where difficulty was experienced in aspiration. It also prevented any possible difficulty in catheter flushing. Increased locking frequency prevents any thrombus accumulation within the temporary catheter, while it has limited but significant preventive effect on thrombus accumulated around the catheter.