Premium
Updating of methods for prevention of HIV transmission during ophthalmological procedures
Author(s) -
Tervo T.,
Laatikainen L.,
Tarkkanen A.,
Valle S.L.,
Tervo K.,
Vaheri A.,
Suni J.
Publication year - 1987
Publication title -
acta ophthalmologica
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.534
H-Index - 87
eISSN - 1755-3768
pISSN - 1755-375X
DOI - 10.1111/j.1755-3768.1987.tb08483.x
Subject(s) - human immunodeficiency virus (hiv) , human decontamination , medicine , transmission (telecommunications) , cross infection , optometry , virology , intensive care medicine , computer science , pathology , telecommunications
. The presence of HIV (human immunodeficiency virus) particles in the tear fluid, on the conjunctival surface or in the contact lenses of patients with chronic HIV infection has made it necessary to establish better for guide‐lines for decontamination of instruments during ophthalmological procedures. The methods are now at the stage of evolution. The present paper describes the disinfection procedures used in the Helsinki University Eye Hospital and updates the present decontamination protocols.