A Method for Rapid Determination of Re and Os Isotope Compositions Using ID‐MC‐ICP‐MS Combined with the Sparging Method
Author(s) -
Nozaki Tatsuo,
Suzuki Katsuhiko,
Ravizza Gregory,
Kimura JunIchi,
Chang Qing
Publication year - 2012
Publication title -
geostandards and geoanalytical research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.037
H-Index - 73
eISSN - 1751-908X
pISSN - 1639-4488
DOI - 10.1111/j.1751-908x.2011.00125.x
Subject(s) - isotope , isotope dilution , chemistry , analytical chemistry (journal) , inductively coupled plasma mass spectrometry , mass spectrometry , chromatography , radiochemistry , physics , quantum mechanics
A simple, rapid method for the determination of Re and Os concentrations and isotope compositions using isotope dilution multi‐collector inductively coupled plasma‐mass spectrometry (ID‐MC‐ICP‐MS) combined with Carius tube digestion and sparging introduction of Os was developed. For Os measurement, four channeltron ion counters to detect different Os isotopes were used simultaneously, which led to a drastic reduction in the measurement time. Rhenium isotopes were measured by means of eight Faraday cups with solution nebulisation and an ultrasonic membrane desolvator. The representative 188 Os count rate of an Os standard solution containing 50 pg of total Os was approximately 110000–120000 cps at the onset of measurement; the Re intensity of our in‐house 10 pg g −1 standard solution reached 1820 V/μg g −1 with a sample uptake rate of 95–99 μl min −1 . These values indicate that the sensitivity of the method was sufficient even for samples with low Re and Os concentrations, such as chert. As the temporal variations of the amplification efficiency of the ion counters differed from one another, we adopted a sample‐calibrator bracketing method to correct the measured Re and Os isotope ratios. The Re and Os concentrations via the isotope dilution method and the 187 Os/ 188 Os ratios of two sedimentary rock reference materials (JMS‐2 and JCh‐1) on the basis of the isotope ratios determined by the MC‐ICP‐MS and by negative thermal ionisation mass spectrometry (N‐TIMS) were comparable within their ranges. Based on Os isotope measurement of the IAG reference material [Durham Romil Os (DROsS)], the average difference from the recommended value and precision of Os isotope measurements by the sparging method in combination with multi‐ion‐counters were 0.72% and 0.76% [1RSD (%), n = 29], respectively. The precisions in the 187 Os/ 188 Os ratios [1RSD (%)] of JMS‐2, JCh‐1 and DROsS were 0.35–0.71, 1.56–3.31 and 0.99–1.28%, respectively, which depended on their Os ion intensities. No systematic difference was observed between the Re and Os geochemical compositions of JCh‐1 and JMS‐2 obtained by means of digestion with inverse aqua regia and CrO 3 ‐H 2 SO 4 solutions, suggesting that either acid solution can be used for the sparging method of sedimentary rock samples. As CrO 3 ‐H 2 SO 4 solution is believed to liberate predominantly the hydrogenous Re and Os fraction from organic‐rich sediment, the sparging method combined with CrO 3 ‐H 2 SO 4 digestion and multi‐ion‐counters in the mass spectrometry is expected to be a powerful tool for reconstructing the secular change in marine Os isotope compositions with high sample throughput.