Numerical investigation of the effects of combining sewer junction characteristics on the hydraulic parameters of flow in fully surcharged condition
Author(s) -
Yekani Motlagh Yaser,
Nazemi Amir H.,
Sadraddini Ali A.,
Abbaspour Akram,
Yekani Motlagh Saber
Publication year - 2013
Publication title -
water and environment journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.437
H-Index - 37
eISSN - 1747-6593
pISSN - 1747-6585
DOI - 10.1111/j.1747-6593.2012.00347.x
Subject(s) - outflow , inflow , hydraulics , volumetric flow rate , flow (mathematics) , geotechnical engineering , mechanics , flow conditions , geology , hydraulic structure , joint (building) , materials science , structural engineering , engineering , oceanography , physics , aerospace engineering
In this study, the effects of different parameters on flow structure and flow hydraulics for combining sewer junction consisting of manhole and lateral inflow were investigated numerically. For this purpose, the effects of dimension variations, main and lateral pipe slope, angle and the joint position of lateral pipe beside manhole, manhole geometry, and the outflow rate of manhole on flow structure and energy loss coefficients were investigated. Results show that the rate of energy loss decreases by heightening the installation position of lateral pipe beside manhole. In addition, it was shown that the slope variations of main and lateral pipes and outflow rate do not affect the rate of energy loss.