z-logo
Premium
CNC‐Milled Titanium Frameworks Supported by Implants in the Edentulous Jaw: A 10‐Year Comparative Clinical Study
Author(s) -
Örtorp Anders,
Jemt Torsten
Publication year - 2012
Publication title -
clinical implant dentistry and related research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.338
H-Index - 85
eISSN - 1708-8208
pISSN - 1523-0899
DOI - 10.1111/j.1708-8208.2009.00232.x
Subject(s) - dentistry , medicine , titanium , orthodontics , materials science , metallurgy
Background: No long‐term clinical studies covering more than 5 years are available on Computer Numeric Controlled (CNC) milled titanium frameworks. Aim: To evaluate and compare the clinical and radiographic performance of implant‐supported prostheses provided with CNC titanium frameworks in the edentulous jaw with prostheses with cast gold‐alloy frameworks during the first 10 years of function. Material and Methods: Altogether, 126 edentulous patients were by random provided with 67 prostheses with titanium frameworks (test) in 23 maxillas and 44 mandibles, and with 62 prostheses with gold‐alloy castings (control) in 31 maxillas and 31 mandibles. Clinical and radiographic 10‐year data were collected for the groups and statistically compared on patient level. Results: The 10‐year prosthesis and implant cumulative survival rate was 95.6% compared with 98.3%, and 95.0% compared with 97.9% for test and control groups, respectively ( p  > .05). No implants were lost after 5 years of follow‐up. Smokers lost more implants than nonsmokers after 5 years of follow‐up ( p  < .01). Mean marginal bone loss in the test group was 0.7 mm (SD 0.61) and 0.7 mm (SD 0.85) in the maxilla and mandible, with similar pattern in the control group ( p  > .05), respectively. One prosthesis was lost in each group due to loss of implants, and one prosthesis failed due to framework fracture in the test group. Two metal fractures were registered in each group. More appointments of maintenance were needed for the prostheses in the maxilla compared with those in the mandible ( p  < .001). Conclusion: The frequency of complications was low with similar clinical and radiological performance for both groups during 10 years. CNC‐milled titanium frameworks are a viable alternative to gold‐alloy castings for restoring patients with implant‐supported prostheses in the edentulous jaw.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here