Premium
Effect of disinfecting solutions on accuracy of alginate and elastomeric impressions
Author(s) -
PEUTZFELDT ANNE,
ASMUSSEN ERIK
Publication year - 1989
Publication title -
european journal of oral sciences
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.802
H-Index - 93
eISSN - 1600-0722
pISSN - 0909-8836
DOI - 10.1111/j.1600-0722.1989.tb01463.x
Subject(s) - impression , elastomer , shrinkage , immersion (mathematics) , materials science , composite material , mathematics , computer science , world wide web , pure mathematics
— The effect of immersion in six disinfecting solutions on the accuracy of 10 impression materials was investigated. Impressions were taken of a truncated steel cone. After setting, the impressions were either stored at room temperature for 24 h, for control, or immediately immersed in a disinfecting agent for 60 min (in one case 10 iron), and after 24 h poured with gypsum. A steel ring fitting the steel cone was placed on the resulting dies, and the discrepancy between the top surface of the ring and the die was measured. From these measurements the deviation between the base diameter of the die and of the impression was calculated to express the inaccuracy. All impressions except some in Blueprint exhibited a net shrinkage, giving rise to too large die stones and incomplete seating of the steel ring. Blueprint impressions, however, occasionally swelled and resulted in too small die stones and “overseating” of the steel ring. The disinfecting solutions had no significant impact on two impression materials. For the remaining eight materials the accuracy was decreased, increased, or unaffected by the immersion. Generally, the accuracy of the alginates investigated were more affected by the disinfecting solutions than were the elastomeric impression materials. The accuracy of the three alginates was drastically impaired by immersion in 70% ethanol, whereas the remaining five disinfecting solutions had a smaller, though sometimes statistically significant, effect on the accuracy. For the elastomeric materials only a few specific combinations of impression material and disinfecting solution reduced the accuracy. Since the control values of accuracy varied, it was concluded that the choice of elastomeric impression material is more critical than the choice of disinfecting agent. As for the alginates, brand as well as type of disinfecting solution have to be considered to obtain an acceptable accuracy of disinfected alginate impressions.