z-logo
Premium
Algor Mortis: An Erroneous Measurement Following Postmortem Refrigeration *
Author(s) -
Wardak Khalil S.,
Cina Stephen J.
Publication year - 2011
Publication title -
journal of forensic sciences
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.715
H-Index - 96
eISSN - 1556-4029
pISSN - 0022-1198
DOI - 10.1111/j.1556-4029.2011.01811.x
Subject(s) - rigor mortis , refrigeration , forensic engineering , engineering , medicine , mechanical engineering , anatomy
  Determination of the time of death is one goal of medicolegal death investigations. Algor mortis has been used as a measure of the postmortem interval (PMI). We prospectively recorded the core temperatures of 19 adult bodies entering our morgue cooler and at 3, 6, and 9 h of refrigeration. We then compared the cooling rate with the calculated body mass index (BMI). For each individual body, the rate of cooling was fairly linear with no evidence of a plateau. There was fair to moderate correlation between the BMI and the cooling rate: cooling rate = −0.052 (BMI) + 3.52. The probability of linearity in any given case was 36%. Variables affecting this correlation included the presence and the layers of clothing and if the clothing was wet. Our data confirm that algor mortis is of very limited utility in determining the PMI in bodies that have been refrigerated.

This content is not available in your region!