z-logo
Premium
Monitoring Complex Secundum Atrial Septal Defects Percutaneous Closure with Real Time Three‐Dimensional Echocardiography
Author(s) -
GarcíaFuertes Daniel,
MesaRubio Dolores,
RuizOrtiz Martín,
DelgadoOrtega Mónica,
TejeroMateo Ignacio,
PanÁlvarezOssorio Manuel,
SuárezdeLezo José,
Lafuente Mercedes
Publication year - 2012
Publication title -
echocardiography
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.404
H-Index - 62
eISSN - 1540-8175
pISSN - 0742-2822
DOI - 10.1111/j.1540-8175.2012.01679.x
Subject(s) - septum secundum , medicine , percutaneous , atrial septum , cardiology , catheter , shunt (medical) , heart septal defect , cardiac catheterization , radiology , shunting , surgery
Background: Atrial septal defect (ASD) is one of the most common congenital heart diseases. Nowadays, percutaneous closure is considered the treatment of choice in most of secundum ASDs. Assessment of the defect and procedure monitoring have been usually performed by angiographic balloon‐sizing and/or two‐dimensional (2D) transesophageal echocardiography. However, in complex ASDs these techniques might be inaccurate. Methods: From January 2009 to January 2011 all adult patients with complex ASDs submitted for percutaneous closure were selected. Those defects, where shunts were present through a device previously implanted on the atrial septum or through multiperforated septums, were considered complex ASDs. Two‐dimensional transesophageal echocardiography and real time three‐dimensional (3D) echocardiography were performed simultaneously during the percutaneous closure procedure. Number of orifices, relationships between the defect, catheter, and device, as well as residual shunt were assessed. Results: Seven patients were included. Five patients had a multiperforated septum and in two cases the defect in the septum was through a previously implanted device. In all cases, 3D echocardiography was superior to 2D echocardiography in relation to the assessment of the relationship between the defect and the catheter or the device. Mechanisms responsible for residual shunts through a device were also better assessed by 3D echocardiography. Conclusion: Three‐dimensional echocardiography is a safe and useful technique when monitoring percutaneous closure of ASDs, showing relevant advantages over 2D echocardiography. (Echocardiography 2012;29:729‐734)

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here