z-logo
Premium
Clinical Value of Noninducibility by High‐Dose Isoproterenol Versus Rapid Atrial Pacing After Catheter Ablation of Paroxysmal Atrial Fibrillation
Author(s) -
CRAWFORD THOMAS,
CHUGH AMAN,
GOOD ERIC,
YOSHIDA KENTARO,
JONGNARANGSIN KRIT,
EBINGER MATTHEW,
PELOSI Jr. FRANK,
BOGUN FRANK,
MORADY FRED,
ORAL HAKAN
Publication year - 2010
Publication title -
journal of cardiovascular electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.193
H-Index - 138
eISSN - 1540-8167
pISSN - 1045-3873
DOI - 10.1111/j.1540-8167.2009.01571.x
Subject(s) - medicine , pulmonary vein , atrial fibrillation , cardiology , ablation , atrial flutter , catheter ablation , sinus rhythm
Noninducibility by High‐Dose Isoproterenol.   Objective: To determine the relative clinical value of noninducibility of atrial fibrillation (AF) by isoproterenol (ISO) and by rapid atrial pacing (RAP) in patients with paroxysmal AF (PAF).Background:AF can be induced by RAP or ISO in >85% of patients with PAF.Methods:ISO was administered in escalating doses of 5, 10, 15, and 20 μg/min in 112 patients (age = 56 ± 13 years) with PAF before radiofrequency catheter ablation. AF was inducible in 97 of 112 patients (87%) at a mean dose of 15 ± 5 μg/min. RAP induced AF in the remaining 14 of 15 patients. Antral pulmonary vein (PV) isolation (APVI) was followed by ablation of complex fractionated atrial electrograms (CFAEs) as necessary to terminate AF and render AF noninducible in response to ISO.Results:AF terminated during APVI in 72 of 111 patients (65%) and after APVI plus ablation of CFAEs in 11 of 111 patients (10%). In the remaining 28 patients (25%), sinus rhythm was restored by transthoracic cardioversion. RAP was performed in the last 61 consecutive patients who were rendered noninducible by ISO. RAP initiated AF in 20 of 61 patients (33%) and atrial flutter in 6 patients (10%). No additional ablation was performed if AF was induced with RAP; however, atrial flutter was targeted. At 12 ± 5 months, 63/75 patients (84%) who were noninducible by ISO and 2 of 8 (25%) who still were reinducible by ISO were free from recurrent AF after a single ablation procedure without antiarrhythmic drugs (P = 0.001). AF recurred in 20 of 36 patients (56%) who required cardioversion for persistent AF after ablation (P < 0.001). Among the 61 patients who also underwent RAP, 12 of 20 (60%) who were, and 31 of 41 (76%) who were not inducible by RAP were free from recurrent AF (P = 0.21). The accuracy of noninducibility as a predictor of clinical outcome was 83% with ISO and 64% by RAP (P = 0.03).Conclusions:The response to isoproterenol after catheter ablation of PAF more accurately predicts clinical outcome than the response to RAP. (J Cardiovasc Electrophysiol, Vol. 21, pp. 13–20, January 2010)

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here