Premium
Complex Electrograms Within the Coronary Sinus: Time‐ and Frequency‐Domain Characteristics, Effects of Antral Pulmonary Vein Isolation, and Relationship to Clinical Outcome in Patients with Paroxysmal and Persistent Atrial Fibrillation
Author(s) -
YOSHIDA KENTARO,
ULFARSSON MAGNUS,
TADA HIROSHI,
CHUGH AMAN,
GOOD ERIC,
KUHNE MICHAEL,
CRAWFORD THOMAS,
SARRAZIN JEAN F.,
CHALFOUN NAGIB,
WELLS DARRYL,
JONGNARANGSIN KRIT,
PELOSI FRANK,
BOGUN FRANK,
MORADY FRED,
ORAL HAKAN
Publication year - 2008
Publication title -
journal of cardiovascular electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.193
H-Index - 138
eISSN - 1540-8167
pISSN - 1045-3873
DOI - 10.1111/j.1540-8167.2008.01175.x
Subject(s) - medicine , pulmonary vein , cardiology , atrial fibrillation , paroxysmal atrial fibrillation , ablation , antrum , coronary sinus , catheter ablation , sinus rhythm , stomach
Background:The mechanistic and clinical significance of complex fractionated atrial electrograms (CFAE) in the coronary sinus (CS) has been unclear.Methods and Results:Antral pulmonary vein isolation (APVI) was performed in 77 patients with paroxysmal (32) or persistent AF (45). CS electrograms recorded for 60 seconds before and after APVI were analyzed in the time‐ and frequency‐domains. Dominant frequency (DF), complexity index (CI: change in polarity of depolarization), and fractionation index (FI: change in direction of depolarization slope) were determined. Before APVI, there was no difference in DF, CI, or FI between paroxysmal and persistent AF. APVI resulted in a significant decrease in DF, CI, and FI in all patients. Baseline CI (43 ± 13/s vs 54 ± 14/s, P = 0.03) and FI (64 ± 23/s vs 87 ± 30/s, P = 0.02) were lower in patients with paroxysmal AF who had AF terminated by ablation than who did not. At 10 ± 2 months, 69% of patients with paroxysmal AF and 49% of patients with persistent AF were free from AF after single ablation. Baseline CI was higher among patients with paroxysmal AF who had AF after APVI (56 ± 20/s vs 44 ± 10/s, P = 0.03). In patients with persistent AF, there was a larger decrease in DF after APVI among patients who remained free from AF (13 ± 11% vs 7 ± 9%, P < 0.05).Conclusions:Complexity of CS electrograms may reflect drivers of AF that perpetuate paroxysmal AF after APVI. In persistent AF, the extent to which APVI decreases DF in the CS correlates with efficacy, suggesting that DF identifies patients who may require additional ablation beyond APVI.