z-logo
Premium
Early Recurrence of Ventricular Fibrillation After Successful Defibrillation During Prolonged Global Ischemia in Isolated Rabbit Hearts
Author(s) -
WU TSUJUEY,
LIN SHIENFONG,
HSIEH YUCHENG,
CHEN PENGSHENG,
TING CHIHTAI
Publication year - 2008
Publication title -
journal of cardiovascular electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.193
H-Index - 138
eISSN - 1540-8167
pISSN - 1045-3873
DOI - 10.1111/j.1540-8167.2007.00979.x
Subject(s) - defibrillation , medicine , ventricular fibrillation , cardiology , ischemia , interventricular septum , shock (circulatory) , defibrillation threshold , anesthesia , sinus rhythm , atrial fibrillation , ventricle
The mechanisms that lower the efficacy of electrical defibrillation during prolonged global ischemia remain unclear. Methods and Results : Epicardial activation patterns during attempted electrical defibrillation were studied in 18 Langendorff‐perfused rabbit hearts at baseline, after 5‐minute no‐flow global ischemia and after 10‐minute reperfusion. DFT 50 (voltage required to achieve 50% probability of successful defibrillation) was determined at each stage. Defibrillation was considered successful if postshock sinus/idioventricular rhythm was present. Prolonged global ischemia converted type 1 VF (multiple wandering wavelets) into type 2 VF (repetitive epicardial breakthroughs, REBs). The mean DFT 50 after 5‐minute ischemia (96 ± 39 V) was significantly lower when compared with that at baseline (154 ± 47 V, P < 0.0001) and after 10‐minute reperfusion (145 ± 47 V, P < 0.001). However, the incidence of early (within 10 seconds) VF recurrence after successful shock during prolonged global ischemia (23 of 78, 29.5%) was much higher than that at baseline (2 of 60, 3.3%) and after 10‐minute reperfusion (5 of 63, 7.9%; P < 0.0001). Mapping data showed that the VF wavefronts during prolonged global ischemia were initially halted by the shock, followed by one to five ventricular escape beats. These beats then triggered REBs and early VF recurrence. In eight out of 11 episodes, the REBs before and after successful shock arose from the same location near the interventricular septum. Conclusions : There is a significant reduction of DFT 50 during prolonged global ischemia. However, defibrillation appears to fail when the preexisting REBs near the interventricular septum induce early VF recurrence. Shock per se cannot eliminate the substrates of these REBs.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here