z-logo
Premium
Near Elimination of Ventricular Pacing in SafeR Mode Compared to DDD Modes: A Randomized Study of 422 Patients
Author(s) -
DAVY JEANMARC,
HOFFMANN ELLEN,
FREY AXEL,
JOCHAM KURT,
ROSSI STEFANO,
DUPUIS JEANMARC,
FRABETTI LORENZO,
DUCLOUX PASCALE,
PRADES EMMANUEL,
JAUVERT GAËL
Publication year - 2012
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1111/j.1540-8159.2011.03314.x
Subject(s) - medicine , safer , bradycardia , cardiology , atrial fibrillation , randomized controlled trial , atrioventricular block , tachycardia , anesthesia , heart rate , blood pressure , computer security , computer science
Aims:SafeR performance versus DDD/automatic mode conversion (DDD/AMC) and DDD with a 250‐ms atrioventricular (AV) delay (DDD/LD) modes was assessed toward ventricular pacing (Vp) reduction .Methods:  After a 1‐month run‐in phase, recipients of dual‐chamber pacemakers without persistent AV block and persistent atrial fibrillation (AF) were randomly assigned to SafeR, DDD/AMC, or DDD/LD in a 1:1:1 design. The main endpoint was the percentage of Vp (%Vp) at 2 months and 1 year after randomization, ascertained from device memories. Secondary endpoints include %Vp at 1 year according to pacing indication and 1‐year AF incidence based on automatic mode switch device stored episodes .Results:  Among 422 randomized patients (73.2 ± 10.6 years, 50% men, sinus node dysfunction 47.4%, paroxysmal AV block 30.3%, bradycardia‐tachycardia syndrome 21.8%), 141 were assigned to SafeR versus 146 to DDD/AMC and 135 to DDD/LD modes. Mean %Vp at 2 months was 3.4 ± 12.6% in SafeR versus 33.6 ± 34.7% and 14.0 ± 26.0% in DDD/AMC and DDD/LD modes, respectively (P < 0.0001 for both). At 1 year, mean %Vp in SafeR was 4.5 ± 15.3% versus 37.9 ± 34.4% and 16.7 ± 28.0% in DDD/AMC and DDD/LD modes, respectively (P < 0.0001 for both). The proportion of patients in whom Vp was completely eliminated was significantly higher in SafeR (69%) versus DDD/AMC (15%) and DDD/LD (45%) modes (P < 0.0001 for both), regardless of pacing indication. The absolute risk of developing permanent AF or of remaining in AF for >30% of the time was 5.4% lower in SafeR than in the DDD pacing group (ns) .Conclusions:  In this selected patient population, SafeR markedly suppressed unnecessary Vp compared with DDD modes. PACE 2012; 35:392–402)

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom