z-logo
Premium
Prevalence and Persistence of Depression in Patients with Implantable Cardioverter Defibrillator: A 2‐year Longitudinal Study
Author(s) -
SUZUKI TSUYOSHI,
SHIGA TSUYOSHI,
KUWAHARA KAZUE,
KOBAYASHI SAYAKA,
SUZUKI SHINICHI,
NISHIMURA KATSUJI,
SUZUKI ATSUSHI,
EJIMA KOICHIRO,
MANAKA TETSUYUKI,
SHODA MORIO,
ISHIGOOKA JUN,
KASANUKI HIROSHI,
HAGIWARA NOBUHISA
Publication year - 2010
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1111/j.1540-8159.2010.02887.x
Subject(s) - medicine , depression (economics) , implantable cardioverter defibrillator , cardiology , heart failure , coronary artery disease , type d personality , ejection fraction , hypertrophic cardiomyopathy , anxiety , psychiatry , economics , macroeconomics
Background: It is unclear whether depression persists in patients with implantable cardioverter defibrillators (ICDs). We evaluated the prevalence and persistence of depression in ICD patients over a 2‐year period.Methods: The study included 90 consecutively hospitalized patients. Patients underlying heart disease was 24% coronary artery disease, 29% idiopathic dilated cardiomyopathy, 24% hypertrophic cardiomyopathy, 13% idiopathic VF/long QT syndrome and miscellaneous conditions 11%. A secondary indication for ICD implantation was present in 20 patients. All patients completed the Zung Self‐Rating Depression Scale (SDS) at study baseline and at the their routine follow‐up visit 2 years after the baseline questionnaire. Delivery of ICD therapies was tracked throughout the 2 years.Results: Depression, indicated by a Zung SDS index score exceeding 60, was present in 29 (32%) of patients at study baseline. Depression was present in 11/51 (21%) patients scheduled to undergo ICD implantation, 2/2 (100%) patients whose device was upgraded to a CRT‐D, 3/14 (21%) patients who had undergone pulse generator replacement, 7/14 (50%) patients who experienced electrical storm and 6/9 (66%) patients hospitalized with acute decompensated heart failure. NYHA functional class III was significantly associated with depression at baseline (HR 6.7, 95% CI 1.68–27.2, p = 0.0007). No differences were noted for female gender, demographics, β‐blocker use, or LVEF ≤35% (p = ns). Depression was present in 25 (28%) of patients at 2 years follow‐up, persisting in 21 (72%) of patients whose Zung SDS scores were elevated at baseline. The median time from ICD shock therapy to completion of the 2 year questionnaire was 9 months (range, 1–22). Patients who were depressed (9/25, 36%) experienced more shocks than non‐depressed patients (6/65, 9%) after 2 years (p = 0.002).Conclusions: Depression is not uncommon among patients who meet criteria for ICD implantation and persists over time particularly when functional status is impaired. Depression is associated with a higher incidence shock therapy. (PACE 2010; 33:1455–1461)

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here