z-logo
Premium
Primary Prevention Implantation of Cardioverter Defibrillator without Defibrillation Threshold Testing: 2‐Year Follow‐up
Author(s) -
BIANCHI STEFANO,
RICCI RENATO P.,
BISCIONE FRANCESCO,
SGRECCIA FABRIZIO,
DI BELARDINO NATALE,
ROSSI PIETRO,
GIULI SILVIA,
GRAMMATICO ANDREA,
DE SANTO TIZIANA,
SANTI ELISABETTA,
MERICO MONICA,
PICCIRILLO GIANFRANCO,
AZZOLINI PAOLO,
SANTINI MASSIMO,
PUGLISI ANDREA
Publication year - 2009
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1111/j.1540-8159.2009.02329.x
Subject(s) - medicine , defibrillation threshold , ventricular fibrillation , implantable cardioverter defibrillator , ventricular tachycardia , cardiology , ejection fraction , incidence (geometry) , sudden cardiac death , defibrillation , ischemic cardiomyopathy , dilated cardiomyopathy , heart failure , physics , optics
Background: Even though the intraoperative threshold testing of the implantable cardioverter defibrillator ( ICD ) may cause hemodynamic impairment or be unfeasible, it is still considered required standard practice at the time of implantation. We compared the outcome of ICD recipients who underwent defibrillation threshold testing (DFT) with that of patients in whom no testing was performed.Methods: A total of 291 subjects with ischemic dilated cardiomyopathy received transvenous ICDs between January 2000 and December 2004 in five Italian cardiology centers. In two centers, DFT was routinely performed in 137 patients (81% men; mean age 69 ± 9 years; mean ejection fraction 26 ± 4%) (DFT group), while three centers never performed DFT in 154 patients (90% men; mean age 69 ± 9 years; mean ejection fraction 27 ± 5%) (no‐DFT group).Results: We compared total mortality, total cardiovascular mortality, sudden cardiac death (SCD), and spontaneous episodes of ventricular arrhythmia (sustained ventricular tachycardia, VT, and ventricular fibrillation, VF) between these groups 2 years after implantation (median 23 months, 25th–75th percentile, 12–44 months). On comparing the DFT and no‐DFT groups, we found an overall mortality rate of 20% versus 16%, cardiovascular mortality of 13% versus 10%, SCD of 3% versus 0.6%, VT incidence of 8% versus 10%, and VF incidence of 6% versus 4% (no significant difference in any comparison).Conclusions: No significant differences in the incidence of clinical outcomes considered emerged between no‐DFT and DFT groups. These results should be confirmed in larger prospective studies.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here