z-logo
Premium
Successful Radiofrequency Catheter Ablation of Ventricular Tachycardia Originating from Underneath the Mechanical Prosthetic Aortic Valve
Author(s) -
YAMADA TAKUMI,
McELDERRY H. THOMAS,
DOPPALAPUDI HARISH,
NEAL KAY G.
Publication year - 2008
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1111/j.1540-8159.2008.01052.x
Subject(s) - medicine , cardiology , ablation , ventricular tachycardia , catheter ablation , aortic valve , catheter , tachycardia , mechanical valve , surgery
A 67‐year‐old man who developed sustained ventricular tachycardia (VT) 4 years after a prosthetic aortic valve replacement, underwent electrophysiologic testing and catheter ablation. The mechanism of the VT was suggested to be triggered activity because the VT could be induced by programmed ventricular stimulation, and burst ventricular pacing demonstrated overdrive suppression without a transient entrainment. Successful catheter ablation using a transseptal approach was achieved underneath the mechanical prosthetic aortic valve on the blind side for that approach. This case demonstrated that catheter mapping and ablation of the entire LV using a transseptal approach might be possible.