z-logo
Premium
Internal Cardioversion of Chronic Atrial Fibrillation in Patients
Author(s) -
NERI ROBERTO,
PALERMO PIERO,
CESARIO ANTONIO SILVIO,
BARAGLI DANIELA,
AMICI ELISABETTA,
GAMBELLI GIANCARLO
Publication year - 1997
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1111/j.1540-8159.1997.tb04242.x
Subject(s) - medicine , cardioversion , cardiology , defibrillation , atrial fibrillation , defibrillation threshold , coronary sinus , sedation , shock (circulatory) , tolerability , sinus rhythm , anesthesia , adverse effect
Transvenous internal cardioversion of chronic AF using a right atrium (RA) coronary sinus (CS) vector requires more energy than cardioversion of paroxysmal AF. Chronic AF is not terminated in 25% of patients using biphasic shocks up to 10 J. We therefore evaluated efficacy, safety, and tolerability of internal cardioversion using a “unipolar’ configuration (RA to skin patch) and biphasic shocks in patients with long‐lasting AF and different heart disease. In each patient, biphasic R have synchronous shocks were delivered between a large defibrillating surface area electrode in the RA and a skin patch in the left prepectoral position. Defibrillation protocol started with a test shock of 0.4 J. Shocks were repeated and increased until termination of AF or a maximum of 34 J. Sedation was used when the patient described the shock as painful. This study included 11 patients with a mean age of 67 ± 8 years (range 56–83). AF duration was ± 1 month in all patients with a mean duration of 11 ± 11 months (range 2–36). Underlying heart disease was present in all patients and the mean left atrial dimension was 43 ± 9 mm (range 26–57). AF was terminated in 10 of 11 patients (91 %) with a mean delivered energy of the successful shocks of 18.7 ± 8.7 J (median energy 16.9 J; range 7.3–32.5) and a mean leading edge voltage of 564 ± 129 V. The mean shock impedance at the defibrillation threshold was 71 ± 13 Ω, (range 59–103). A total of 131 shocks were delivered without any complication and proarrhythmia episodes. We conclude that low energy “unipolar” internal cardioversion is a simple, safe, and effective technique for termination of chronic AF in patients with heart disease. The procedure is often tolerated under light sedation.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here