Objective: The goal of this study was to assess if tilt bears any impact on defibrillation efficacy of biphasic shocks. Background: Although it has been shown that hiphasic waveform may increase the defibrillation efficacy, this pulsing method has not been as extensively studied in patients, and information regarding the effect of different tilts is lacking. Methods: This study consisted of two similar but distinct protocols including 33 patients undergoing transvenous defibriilator implant. In 17 patients (Part I) defibrillation threshold was obtained delivering biphasic waveforms with 50%, 65%, and 80% tilt in random fashion. Similarly, in 16 patients (Part II) testing of biphasic waveform with 40%, 50%, and 65% tilt was performed in random order. The electrode system used consisted of two transvenous leads and a subcutaneous patch in all 33 patients. Results: In Part I, tilt of 50% demonstrated a defibrillation threshold significantly lower than 65% tilt (7.5 ± 4.3 J vs 9.7 ± 5.0 J; P = 0.04) and 80% tilt (7.5 ± 4.3) vs 11.7 ± 5.9 J; P < 0.01). Similarly, 65% tilt provided a lower defibrillation threshold than 80% tilt (9.7 ± 5.0 J vs 11.7 ± 5.9 J; P = 0.02). In Part II, no significant difference was observed in terms of defibriilation threshold between 40% tilt and the two tilts of 50% and 65%. However, as in Part I, 50% tilt provided a significant reduction of the energy to defibrillate as compared to 65% tilt (6.3 ± 3.6 J vs 9.0 ± 4.8 J; P < 0.01). The 50% tilt resulted in better defibrillation efficacy than 65% tilt independent of the lead system used for testing (Medtronic Transvene and CPI Endotak‐C). Conclusions: Biphasic shocks with 50% tilt required less energy for defibrillation than 40%, 65%, and 80% tilts. However, in the clinical setting a programmable tilt may be preferable to account for some patient‐to‐patient variability.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here