z-logo
Premium
Initial Single‐Center Experience with an Advanced Third‐Generation Investigational Defibrillator
Author(s) -
LAMPERT RACHEL,
ROSENFELD LYNDA,
McPHERSON CRAIG,
LEWIS RICHARD,
VANZETTA ALICE,
BATSFORD WILLIAM
Publication year - 1996
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1111/j.1540-8159.1996.tb03281.x
Subject(s) - medicine , defibrillation , defibrillation threshold , cardiology , shock (circulatory) , bradycardia , artificial cardiac pacemaker , implantable cardioverter defibrillator , heart rate , blood pressure
The CPI PRxII is a recently approved, multitiered implantable cardioverter defibrillator (ICD) that delivers high and low energy biphasic shocks, antitachycardia (ATP) and bradycardia pacing, and stores 2.5 minutes of electrograms from the widely spaced shocking electrodes. The PRxII was implanted in 58 patients at Yale‐New Haven Hospital between December 1993 and January 1995. At implant, mean biphasic defibrillation threshold (DFT) in patients with testing to failure was 10 J (1–20). All 36 patients who were candidates for a new transvenous system underwent successful nonthoracotomy implantation. Based on noninvasive predischarge EPS results, 30 patients had ≥ 1VT zone: 21 patients had ATP, 9 others had first shock ≤ 5 J. During follow‐up, 13 patients had been treated for 379 events (range, 1–127). Of 340 events in a zone with ATP, 97% responded to ATP, 3% required shock. First programmed shock converted all events in a VF zone. Details, including RR intervals, were available for ail events in 15 of 17 patients receiving appropriate or inappropriate therapy or diverted shocks. One hundred eleven of 148 available electrograms confirmed VT by morphology, rate, and/or presence of AV dissociation. In nine patients, electrogram data altered therapy through diagnosis of inappropriate or diverted therapy, guidance of detection enhancements, or diagnosis of previously unrecognized VTs. We conclude the PRxII achieves low DFTs that obviate the need for thoracotomy and effectively treats ventricular arrhythmias with ATP and shock, with programming guided by noninvasive electrophysiology. Multiple stored electrograms from widely spaced shocking electrodes greatly enhance diagnostic capabilities, facilitating effective treatment.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here