Ventricular Pacing Threshold and Time to Capture Postdefibrillation in Patients Undergoing Implantable Cardioverter‐Defibrillator Implantation
Author(s) -
KHASTGIR TERRANCE,
LATTUCA JOHN,
AARONS DIANA,
MURPHY JOSEPH,
O'MARA VICKI,
JUANTEGUY JUAN,
VELTRI ENRICO P.
Publication year - 1991
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1111/j.1540-8159.1991.tb04104.x
Subject(s) - medicine , defibrillation , defibrillation threshold , ventricular fibrillation , amiodarone , cardiology , implantable cardioverter defibrillator , fibrillation , anesthesia , atrial fibrillation
To assess the effect of defibrillation and amiodarone on ventricular pacing threshold and time to capture in patients undergoing automatic implantable cardioverter‐defibrillator (AICD) implantation, 28 patients were prospectively evaluated. The patients were entered into one of two protocols: la—epicardial ventricular pacing threshold measured at baseline (preventricular fibrillation induction) and 10 and 60 seconds postdefibrillation with 20 J, or Ib—two fibrillation‐defibrillation sequences were performed 3 minutes apart and ventricular pacing thresholds were measured for each sequence at baseline and at 10 and 60 seconds postdefibrillation with 20 J. Ten patients also underwent asynchronous pacing at 1.1 times baseline threshold during ventricular fibrillation with measurement of time to capture postdefibrillation. All patients were randomly assigned to receive either amiodarone or no antiarrhythmic drug therapy. Ventricular fibrillation was induced with AC (applied for 1‐2 seconds), and standard epicardial bipolar and epicardial patch electrodes of the AICD were used for pacing and defibrillation, respectively. Ventricular pacing threshold at baseline, 10 seconds, 60 seconds, and 3 minutes postdefibrillation did not differ significantly. There were no significant differences in patients with or without amiodarone therapy. Furthermore, there was no transient loss of ventricular capture postdefibrillation or significant difference in time to capture with amiodarone (≤ 2 seconds). We conclude that following internal defibrillation with 20 J: (1) ventricular pacing threshold at 10 seconds, 60 seconds, and 3 minutes were not significantly different from baseline with one or two fibrillation‐defibrillation sequences, (2) time to capture was short, and (3) there was no significant difference in no drug versus amiodarone. These findings have direct clinical importance in considering device therapy with both pacing and defibrillating capabilities.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here