z-logo
Premium
The Ventricular Depolarization Gradient: Effects of Exercise, Pacing Rate, Epinephrine, and Intrinsic Heart Rate Control on the Right Ventricular Evoked Response
Author(s) -
CALLAGHAN FRANK,
VOLLMANN WILLIAM,
LIVINGSTON ANDREA,
BOVEJA BIRINDER,
ABELS DEBRA
Publication year - 1989
Publication title -
pacing and clinical electrophysiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.686
H-Index - 101
eISSN - 1540-8159
pISSN - 0147-8389
DOI - 10.1111/j.1540-8159.1989.tb01934.x
Subject(s) - medicine , heart rate , epinephrine , depolarization , cardiology , anesthesia , treadmill , blood pressure
A new pacing technique is described that permits high fidelity recording of the paced ventricular evoked response, including cardiac depolarization. Integration of the paced R wave yields the ventricular depolarization gradient (G D ), which is dependent on activation sequence and the spatial dispersion of activation times. G D was studied in 27 dogs to determine the ejects of treadmill exercise at fixed rate pacing (n = 10), elevation of heart rate in the absence of stress (n = 20), epinephrine at fixed rate (n = 6), and exercise in the presence of normal chronotrophic response (n = 7). Low level exercise (1 mph, 2 min, 15°) at a fixed heart rate produced significant (P < 0.0005) decreases in G D that averaged —‐10.8 ± 4.0% (mean ± SD). The rate of change in G D was faster at the onset of exercise than at its cessation (P < 0.0005). Artificial elevation of heart rate at rest produced significant (P < 0.0005) increases in G D ; mean sensitivity of G D to rote was 0.27 ± 0.12%/beats/min. Intravenous injection of epinephrine produced significant (P < 0.001) decreases in G D at two dosage levels (2.5 and 5.0 μg/kg) when evaluated at two baseline pacing rates (150 and 190 beats/min); mean changes in G D were –20.64 ± 0.53% (2.5 μ/kg at 150 beats/min), –25.19 ± 4.20% (5.0 μ/kg at 150 beats/min), –14.18 ± 5.19% (2.5 μ/kg at 190 beats/min), and –24.22 ± 4.94% (5.0 μ/kg at 190 beats/min). Sensitivity of G D to epinephrine was dose‐dependent (P < 0.01) at each baseline rate, but was independent (P > 0.05) of the rate itself. In the presence of a normal chronotropic response. G D remained unchanged (P > 0.5) during exercise in spite of significant elevation in heart rate (105.0 to 167.1 beats/min, P < 0.001). These data suggest the presence of an intrinsic negative‐feedback control mechanism that maintains G D constant in the healthy heart during homeostatic disturbance. Applications in closed‐loop rate adaptive pacing are described.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here