z-logo
Premium
Effects of plasma dilution on tissue factor–induced thrombin generation and thromboelastography: partly compensating role of platelets
Author(s) -
Schols Saskia E.M.,
Feijge Marion A.H.,
Lancé Marcus D.,
Hamulyák Karly,
Ten Cate Hugo,
Heemskerk Johan W. M.,
Van Pampus Elisabeth C.M.
Publication year - 2008
Publication title -
transfusion
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.045
H-Index - 132
eISSN - 1537-2995
pISSN - 0041-1132
DOI - 10.1111/j.1537-2995.2008.01872.x
Subject(s) - thromboelastography , coagulation , chemistry , hemostasis , fibrin , thrombin , tissue factor , platelet , dilution , fibrinogen , thromboelastometry , anesthesia , medicine , immunology , biochemistry , physics , thermodynamics
BACKGROUND: Bleeding upon major surgery or severe trauma is treated by transfusion with crystalloids, colloids, or plasma. This treatment, however, can lead to dilutional coagulopathy and impaired hemostasis. We investigated the suitability of two integrative coagulation tests to measure the hemostatic activity of diluted plasma. STUDY DESIGN AND METHODS: Plasma from healthy donors was diluted in vitro with saline or colloid (venofundin or gelofusin). Coagulant activity in response to tissue factor was monitored by calibrated automated thrombin (CAT) generation and rotational thromboelastography (TEG), detecting formation of elastic fibrin clots. Plasma from patients receiving fluid infusion during coronary artery bypass grafting (CABG) was analyzed with the same assays. RESULTS: Optimal activity of CAT and TEG assays required the presence of 10 pmol per L tissue factor and 4 µmol per L phospholipid vesicles or 100 × 10 9 platelets (PLTs) per L. Strikingly, thrombin generation and clot formation became impaired at a higher extent of dilution with PLTs present (≤40% plasma) than with phospholipid vesicles present (≤60% plasma). Colloids aggravated the dilution effect on clot formation, but FFP antagonized the dilution effect on thrombin and clot formation. In contrast, fibrinogen and Factor (F)XIII only restored the impaired clot formation. In plasma samples from patients undergoing CABG, CAT and TEG assay variables were altered to an extent corresponding with the volume of fluid infusion. CONCLUSION: Thrombin generation and clot formation are reduced at a plasma dilution of more than 40 percent. In either process, PLTs can partly compensate for the dilution effect. In vitro dilution with colloids impaired fibrin clot elasticity compared to saline.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here