z-logo
Premium
Performance‐Based Measures of Physical Function for High‐Function Populations
Author(s) -
Curb J. David,
CeriaUlep Clementina D.,
Rodriguez Beatriz L.,
Grove John,
Guralnik Jack,
Willcox Brad J.,
Donlon Tim A.,
Masaki Kamal H.,
Chen Randi
Publication year - 2006
Publication title -
journal of the american geriatrics society
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.992
H-Index - 232
eISSN - 1532-5415
pISSN - 0002-8614
DOI - 10.1111/j.1532-5415.2006.00700.x
Subject(s) - medicine , grip strength , balance (ability) , physical medicine and rehabilitation , reliability (semiconductor) , physical therapy , test (biology) , population , paleontology , power (physics) , physics , environmental health , quantum mechanics , biology
OBJECTIVES: To improve and broaden the applicability of performance‐based measures of function for use in clinical and research settings. DESIGN: Cross‐sectional repeated‐measures study. SETTING: Research clinic. PARTICIPANTS: Population‐based sample of Japanese Americans without significant functional impairments aged 35 to 55 and 56 to 71 (N=203). MEASUREMENTS: Performance‐based measures of physical function, including range of standard tests, newer automated measures of balance and strength and data on cognitive function, lifestyle, medical history, and physical activity. RESULTS: Of the nonplatform balance measures, only the one‐leg stand was reliable (reliability coefficient (rc) =0.69) and able to discriminate between functional levels. Combining the Fourth National Health and Nutrition Examination Survey protocol of folded arm position while standing on a foam pad with the more‐sophisticated balance platform test had the highest reliability and discrimination. With the strength chair, high rcs (0.88–0.96) were found for upper and lower extremity tests. Timed chair stands, a test of lower extremity and central strength were reliable. The 6‐minute walk had a high rc (0.90). CONCLUSION: Many performance tests used today are not reliable. Only a few discriminate between the most highly functioning individuals and individuals with good function. Thus, a new recommended battery includes unassisted single‐leg stand, balance platform “foam pad, eyes closed,” elbow flexion and knee extension strength (strength chair), grip strength, timed chair stands, and the 6‐minute walk. These simple performance‐based tests have good reliability and discrimination across the range of function and can be used in most clinical and research settings to quickly assess global functional level.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here