z-logo
Premium
A novel instrument for logging nearwork distance
Author(s) -
Leung Tszwing,
Flitcroft Daniel I,
Wallman Josh,
Lee Tat Hing,
Zheng Yongping,
Lam Carly Siuyin,
Kee Cheasu
Publication year - 2011
Publication title -
ophthalmic and physiological optics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.147
H-Index - 66
eISSN - 1475-1313
pISSN - 0275-5408
DOI - 10.1111/j.1475-1313.2010.00814.x
Subject(s) - reading (process) , spectrum analyzer , optometry , medicine , optics , physics , political science , law
Citation information: Leung T‐W, Flitcroft DI, Wallman J, Lee TH, Zheng Y, Lam CS‐Y & Kee C‐S. A novel instrument for logging nearwork distance. Ophthalmic Physiol Opt 2011, 31 , 137–144. doi: 10.1111/j.1475‐1313.2010.00814.x Abstract Purpose:  To validate a novel ultrasonic sensor for logging reading distances. In addition, this device was used to compare the habitual reading distances between low and high myopes. Methods:  First, the stability and sensitivity of the ultrasonic device were determined by repeated measures using artificial targets. Then, thirty Hong Kong Chinese (20–30 years) were recruited, of whom fifteen were considered to be high myopes (mean ± S.D. = −8.7 ± 0.5 D) and 15 to be low to non‐myopes (mean ± S.D. = −2.0 ± 0.2 D). Each subject read a newspaper with their habitual visual aid continuously for 10 min in two sessions at their preferred working distance(s). The reading distances were recorded continuously using a novel nearwork analyzer. The modal working distance was considered as the ‘habitual’ reading distance. In addition, habitual reading distance was reported orally by each subject. Results:  The nearwork analyzer gave accurate and repeatable measurements over a range of distances and angles. Using this instrument, high myopes were found to have a significantly shorter reading distance than low myopes or non‐myopes (mean ± S.D. = 35.9 ± 9.8 cm vs 50.9 ± 24.8 cm; two‐sample t ‐test, p  = 0.04, df = 18). The reading distances reported orally by the subjects were not correlated with those recorded by the nearwork analyzer. Conclusions:  The nearwork analyzer was found to be an effective tool for measuring nearwork reading distance in a small group of emmetropic and myopic adults over a 10 min interval. Differences between the reading distance between high myopes and low/non‐myopes was detected by the device. Further study is needed to determine if a closer working distance is a cause or effect of myopia development.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here