z-logo
Premium
The development and validation of an algorithm for real‐time computerised fetal heart rate monitoring in labour
Author(s) -
Taylor Graham M.,
Mires Gary J.,
Abel Eric W.,
Tsantis Stavros,
Farrell Tom,
Chien Patrick F. W.,
Liu Ying
Publication year - 2000
Publication title -
bjog: an international journal of obstetrics and gynaecology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.157
H-Index - 164
eISSN - 1471-0528
pISSN - 1470-0328
DOI - 10.1111/j.1471-0528.2000.tb11112.x
Subject(s) - intraclass correlation , cardiotocography , cohen's kappa , medicine , correlation coefficient , reliability (semiconductor) , fetal heart rate , kappa , heart rate , mathematics , algorithm , statistics , reproducibility , fetus , pregnancy , power (physics) , physics , geometry , quantum mechanics , blood pressure , biology , genetics
Objective To develop and validate a computerised algorithm for the interpretation of the characteristics of fetal heart rate monitoring in labour. Design Prospective observational study. Setting Labour ward in a tertiary hospital. Sample Intrapartum cardiotocograms from 24 pregnancies. Methods A computerised algorithm was developed to assess the fetal heart baseline rate, variability, the number of accelerations and the number of decelerations. Twenty five minute segments of cardiotocograms were interpreted by the algorithm and also by seven expert reviewers independently. The reviewers were unaware of the outcome of labour. The reliability of the characteristics of car‐diotocography and the validity of the computerised algorithm were assessed using the intraclass correlation coefficient and weighted kappa statistic for continuous and ordinal variables respectively. Results The inter rater reliability of the baseline fetal heart rate and the number and type of decelerations was good (intraclass correlation coefficient 0.93, 0.93 and 0.79, respectively). The reliability of baseline variability (kappa = 0.27) and accelerations (intraclass correlation coefficient = 0.27) was poor. The computerised algorithm had good agreement with the reviewers for the baseline fetal heart rate (intraclass correlation coefficient 0.91 to 0.98) and the number of decelerations (intraclass correlation coefficient 0.82 to 0.91), but was less valid as regards the number of late decelerations (intraclass correlation coefficient 0.68 to 0.85) and the number of accelerations (intraclass correlation coefficient 0.06 to 0.80), and was invalid as regards baseline variability (kappa 0.00 to 0.34). Conclusions The high level of validity of the computerised algorithm for the estimation of the baseline fetal heart rate and the number of decelerations justifies its further technical development.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here