z-logo
Premium
Biodegradable braided poly(lactic‐co‐glycolic acid) urethral stent combined with dutasteride in the treatment of acute urinary retention due to benign prostatic enlargement: a pilot study
Author(s) -
Kotsar Andres,
Isotalo Taina,
Juuti Hanne,
Mikkonen Joonas,
Leppiniemi Jenni,
Hänninen Venla,
Kellomäki Minna,
Talja Martti,
Tammela Teuvo L.J.
Publication year - 2009
Publication title -
bju international
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.773
H-Index - 148
eISSN - 1464-410X
pISSN - 1464-4096
DOI - 10.1111/j.1464-410x.2008.08111.x
Subject(s) - medicine , stent , plga , urinary retention , surgery , catheter , dutasteride , urology , urethra , glycolic acid , urethral stricture , prostate , materials science , cancer , lactic acid , nanoparticle , biology , bacteria , genetics , nanotechnology
OBJECTIVE To evaluate, in a pilot study, the efficacy and safety of combining a braided poly(lactic‐co‐glycolic acid) (PLGA, a copolymer of l ‐lactide and glycolide) urethral stent and dutasteride in the treatment of acute urinary retention (AUR) due to benign prostatic enlargement (BPE). PATIENTS AND METHODS Ten men with AUR due to BPE were treated as outpatients. A biodegradable braided PLGA urethral stent was inserted into the prostatic urethra, using a specially designed insertion device under visual control. Dutasteride treatment was started and the patients were followed up for 3 months after insertion of the stents. RESULTS In all patients the stents were placed successfully with the new insertion device. All men were able to void after inserting the stent. At 1 month five patients voided freely with a low residual urine volume (<150 mL), two voided but had a high residual urine volume and a suprapubic catheter was placed, and three needed a suprapubic or an indwelling catheter before 1 month, due to AUR or comorbidities. At 3 months five patients were voiding with no problems. CONCLUSIONS We have developed a new and effective insertion device for biodegradable braided prostatic stents. The new braided‐pattern stent overcomes the earlier problems of migration and sudden breakage into large particles associated with biodegradable spiral stents. However, the mechanical properties of the new stent need to be improved and tested in a longer follow‐up. We consider that this new biodegradable braided‐pattern urethral stent could provide a new option in the future treatment of AUR.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here