z-logo
Premium
Time‐specific intraocular pressure curves in Rhesus macaques ( Macaca mulatta ) with laser‐induced ocular hypertension
Author(s) -
Ollivier F. J.,
Brooks D. E.,
Kallberg M. E.,
Sapp H. L.,
Komáromy A. M.,
Stevens G. R.,
Dawson W. W.,
Sherwood M. B.,
Lambrou G. N.
Publication year - 2004
Publication title -
veterinary ophthalmology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.594
H-Index - 50
eISSN - 1463-5224
pISSN - 1463-5216
DOI - 10.1111/j.1463-5224.2004.00316.x
Subject(s) - intraocular pressure , ophthalmology , medicine , ocular hypertension , glaucoma
Objective  To detect and categorize time‐specific variations in daytime intraocular pressure (IOP) found in Rhesus monkeys with laser‐induced ocular hypertension. Procedures  Ten male monkeys with argon laser‐induced ocular hypertension in one eye were anesthetized with ketamine hydrochloride, and the IOP measured in both eyes at 7 a.m., 7.30 a.m., and then hourly until 1 p.m. with a Tonopen™ XL applanation tonometer. Intraocular pressure time profiles for both eyes in each animal were developed. The means ± SD of the IOPs for both eyes were calculated for the whole 6‐h study period, and the values compared statistically. The difference between the lasered eye mean IOP standard deviation and the normal eye mean IOP standard deviation for each animal during the 6‐h follow‐up was also calculated and compared. Results  Mean IOP (± SD) in the glaucoma and normal eyes for the 10 animals during the 6‐h study was 32.6 ± 2.5 and 14.9 ± 2.5 mmHg, respectively. The IOP was significantly higher in the experimental eye than in the normal eye ( P  = 0.0008). The mean IOP in the lasered eye did not significantly change during the study period, whereas a slight but significant increase in IOP of the normal eye over the study period was recorded ( P  = 0.003). The variance in IOP in the hypertensive eyes was considerably greater than that in the untreated control eyes. From 7 a.m. to 1 p.m. the IOP declined in five eyes and increased in the other five eyes with laser‐induced ocular hypertension. Conclusions  The time‐specific IOP variation pattern in the daytime in the laser treated eyes is significantly greater than the variation in the normotensive eyes. This shows that in order to detect statistical differences between IOP variations induced by an IOP‐reducing drug, and the exaggerated spontaneous IOP variations present in the laser‐induced hypertensive eye, sufficient animals should be included in any study. Understanding the time‐specific IOP variation present in a group of monkeys with laser‐induced ocular hypertension is essential prior to using the model for the evaluation of IOP‐reducing drugs.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here