z-logo
Premium
A deeper level of ketamine anesthesia does not affect functional residual capacity and ventilation distribution in healthy preschool children
Author(s) -
VON UNGERNSTERNBERG BRITTA S,
REGLI ADRIAN,
FREI FRANZ J.,
RITZ EVAMARIA JORDI,
HAMMER JÜRG,
SCHIBLER ANDREAS,
ERB THOMAS O.
Publication year - 2007
Publication title -
pediatric anesthesia
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.704
H-Index - 82
eISSN - 1460-9592
pISSN - 1155-5645
DOI - 10.1111/j.1460-9592.2007.02335.x
Subject(s) - medicine , functional residual capacity , affect (linguistics) , anesthesia , ketamine , ventilation (architecture) , residual , distribution (mathematics) , residual volume , lung volumes , lung , mathematical analysis , linguistics , philosophy , mathematics , algorithm , computer science , mechanical engineering , engineering
Summary Background:  Ketamine is commonly used in children in the emergency setting and while undergoing diagnostic and therapeutic interventions because of its combination of hypnotic and analgesic properties. Although studies comparing various levels of ketamine anesthesia are lacking, previous work suggests that lung mechanics might only be minimally affected by ketamine. Methods:  After approval from the Ethics Committee, anesthesia was induced with 2 mg·kg −1 racemic ketamine followed by a continuous infusion of ketamine 2 mg·kg −1 h −1 (level I) in 26 children (2–6 years of age), and after 5 min, the first set of measurements was performed. Then, a second bolus of ketamine 2 mg·kg −1 followed by ketamine 4 mg·kg −1 h −1 was administered (level II) and after 5 min, the second set of measurements was performed. Functional residual capacity (FRC) and lung clearance index (LCI) were calculated using a multibreath analysis by a blinded observer. Results:  Functional residual capacity and LCI did not change between the two levels (FRC 25.6 [4.3] ml·kg −1 vs 25.5 [4.2] ml·kg −1 , P  = 0.769, LCI 10.5 [1.2] vs 10.3 [1.1], P  = 0.403). The minute ventilation was similar between the two levels of anesthesia. The University of Michigan Sedation Scale increased from 3 (3) to 4 (3–4) at the second level of ketamine anesthesia. Conclusions:  A deeper level of anesthesia induced by ketamine does not affect FRC, ventilation distribution or minute ventilation suggesting that the depth of ketamine anesthesia has a minimal effect on pulmonary function.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here