Premium
Surgical management of vaginal wound healing defects after tension‐free vaginal tape placement
Author(s) -
LEE TACK,
KIM JUNSIG,
JUNG JINKWAN,
LEE HUNJAE
Publication year - 2005
Publication title -
international journal of urology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.172
H-Index - 67
eISSN - 1442-2042
pISSN - 0919-8172
DOI - 10.1111/j.1442-2042.2005.01135.x
Subject(s) - medicine , surgery , wound healing
The use of tension‐free vaginal tape (TVT) made of polypropylene mesh carries the risk of causing vaginal wound healing defects, which are usually detected within 4 weeks of operation. We present three cases of vaginal wound healing defects after TVT procedures. These defects were managed using surgical techniques aimed at preserving the mesh, but all failed. There are many options for dealing with the problems of vaginal wounds following TVT. These include further observation, mesh removal, suturing the wound, or using tissue flaps to cover it. However, the latter two options cannot be recommended as they usually fail.