z-logo
Premium
Prolonged use of continuous glucose monitors in children with type 1 diabetes on continuous subcutaneous insulin infusion or intensive multiple‐daily injection therapy
Author(s) -
Stuart A. Weinzimer,
Dongyuan Xing,
Michael Tansey,
Rosanna FialloScharer,
Nelly Mauras,
Tim Wysocki,
Roy W. Beck,
William V. Tamborlane,
Katrina J. Ruedy
Publication year - 2009
Publication title -
pediatric diabetes
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.678
H-Index - 75
eISSN - 1399-5448
pISSN - 1399-543X
DOI - 10.1111/j.1399-5448.2008.00476.x
Subject(s) - medicine , continuous glucose monitoring , type 1 diabetes , insulin pump , ambulatory , diabetes mellitus , insulin , blood glucose self monitoring , continuous monitoring , emergency medicine , pediatrics , surgery , endocrinology , operations management , economics
Objective:  For continuous glucose sensors to improve the treatment of children with type 1 diabetes (T1D), they must be accurate, comfortable to wear, and easy to use. We conducted a pilot study of the FreeStyle Navigator™ Continuous Glucose Monitoring System (Abbott Diabetes Care) to examine the feasibility of daily use of a continuous glucose monitor (CGM) in an extended ambulatory setting. Methods:  Following a 13‐wk trial of daily Navigator use, 45 children with T1D [10.7 ± 3.7 yr, range 4.6–17.6, 24 using insulin pumps; continuous subcutaneous insulin infusion (CSII) and 21 using glargine‐based multiple daily injections (MDI)] used the Navigator for an additional 13 wk. Results:  Navigator use was initially slightly higher in the CSII users than in the MDI users but declined similarly in both groups by 22–26 wk. After 26 wk, 11 (46%) of 24 CSII users and 7 (33%) of 21 MDI users were using the CGM at least 5 d a week. No baseline demographic or clinical factors were predictive of the amount of sensor use at 26 wk. However, Navigator use during weeks 1–13 and scores on a CGM satisfaction survey at 13 wk were predictive of use in weeks 22–26. Conclusions:  CGM was generally well‐tolerated in children with T1D for more than 6 months, and early acceptance of CGM was predictive of extended use of the device. Although many subjects and parents found CGM valuable, the declining usage over time underscores the need to develop new technologies and strategies to increase acceptance, effectiveness, and long‐term use of these devices in youth with T1D.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here