Premium
Accuracy of in vivo and in vitplo tests
Author(s) -
BindslevJensen C.,
Podsen L. K.
Publication year - 1998
Publication title -
allergy
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.363
H-Index - 173
eISSN - 1398-9995
pISSN - 0105-4538
DOI - 10.1111/j.1398-9995.1998.tb04966.x
Subject(s) - concordance , medicine , placebo , diagnostic test , clinical trial , intensive care medicine , medical physics , pediatrics , pathology , alternative medicine
Any new diagnostic test should be validated by standard procedures, and must be validated by the outcome of double‐blind, placebo‐controlled food challenges (DBPCFC), except in infants, with strict adherence to the EAACI guidelines. Available data should include calculations on sensitivity, specificity, predictive values, and concordance and must be calculated on the basis of patients in whom the diagnosis has been established by DBPCFC. Furthermore, data on possible cross‐reacting foods and their clinical relevance should be available.