Premium
A grinding method for producing sections of large areas of plastic embedded tissues
Author(s) -
Weber Dennis F.,
Eisenmann Dale R.,
Zaki Abd ElMoneim
Publication year - 1982
Publication title -
journal of microscopy
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.569
H-Index - 111
eISSN - 1365-2818
pISSN - 0022-2720
DOI - 10.1111/j.1365-2818.1982.tb00422.x
Subject(s) - grinding , materials science , biomedical engineering , computer science , metallurgy , engineering drawing , medicine , engineering
SUMMARY We have developed a method utilizing relatively thick ground sections of plastic embedded tissue which affords the resolution obtained with 0·5 μm cut sections. The sections, which are permanently affixed to plastic microscope slides, are much larger in area than ultramicrotome sections. Additional advantages are: sections can be destained and restained and selected areas can be examined with various forms of electron microscopy. Autoradiographic studies are also possible. Although the method has a broader application, it is particularly useful in examining the interface between hard and soft tissues.