DOI - 10.1111/j.1365-2710.1995.tb00656.x
Subject(s) - nifedipine , dissolution , chemistry , chromatography , in vitro , dissolution testing , pharmacology , paddle , materials science , medicine , biochemistry , organic chemistry , calcium , composite material , biopharmaceutics classification system
SUMMARY The in vitro dissolution rates of 5 and 10 mg nifedipine capsules from eight suppliers were measured in simulated gastric fluid using the rotating paddle apparatus. A total of fourteen products were tested and the performance was found to be satisfactory for all products (>80% dissolution in 20 min).